| 2018-12-06 10:02:23 | |
| | ****CORRECTIONS**** |
| | |
| | PETER E VALENTI |
| | BUILDING PLANS EXAMINER |
| | [email protected] |
| | 561-805-6673 |
| | |
| | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) |
| | FBC B = FBC BUILDING |
| | FBC EB = FBC EXISTING BUILDING |
| | FBC A = FBC ACCESSIBILITY |
| | FBC EC = FBC ENERGY CONSERVATION |
| | FBC R = FBC RESIDENTIAL |
| | |
| | 1.PLEASE PROVIDE PRODUCT APPROVALS FOR ROOF TILES AND |
| | UNDERLAYMENT/BASE MATERIAL. FBC 107.1 |
| | 2.PLEASE PROVIDE MANUFACTURER?S INSTRUCTIONS FOR THE |
| | VENTED HOOD AND GAS GRILL SHOWN IN SHEET 1. FBC 107.1 |
| | 3.PROVIDE LOCATION WITH ATTACHMENTS DETAILS AND EXHAUST |
| | LOCATION(INCLUDING TERMINATION) FOR THE VENTED HOOD. |
| | FBCR 1307.1 AND 1307.2 |
| | 4.THE STUCCO DETAIL NEEDS ADDITIONAL LAYER OF WATER |
| | BARRIER. |
| | R703.7.3 WATER-RESISTIVE BARRIERS. |
| | WATER-RESISTIVE BARRIERS SHALL BE INSTALLED AS REQUIRED |
| | IN SECTION R703.2 AND, WHERE APPLIED OVER WOOD-BASED |
| | SHEATHING, SHALL INCLUDE A WATER-RESISTIVE |
| | VAPOR-PERMEABLE BARRIER WITH A PERFORMANCE AT LEAST |
| | EQUIVALENT TO TWO LAYERS OF GRADE D PAPER. THE |
| | INDIVIDUAL LAYERS SHALL BE INSTALLED INDEPENDENTLY SUCH |
| | THAT EACH LAYER PROVIDES A SEPARATE CONTINUOUS PLANE |
| | AND ANY FLASHING (INSTALLED IN ACCORDANCE WITH SECTION |
| | R703.4) INTENDED TO DRAIN TO THE WATER-RESISTIVE |
| | BARRIER IS DIRECTED BETWEEN THE LAYERS. |
| | EXCEPTION: WHERE THE WATER-RESISTIVE BARRIER THAT IS |
| | APPLIED OVER WOOD-BASED SHEATHING HAS A WATER |
| | RESISTANCE EQUAL TO OR GREATER THAN THAT OF 60-MINUTE |
| | GRADE D PAPER AND IS SEPARATED FROM THE STUCCO BY AN |
| | INTERVENING, SUBSTANTIALLY NONWATER-ABSORBING LAYER OR |
| | DESIGNED DRAINAGE SPACE. |
| | 5.PLEASE PROVIDE DECK RAFTERS SIZE. FBC 107.2 |
| | 6.PLEASE PROVIDE THE SPACING FOR THE #5 FILL CELLS |
| | REBAR. FBC 107.2.1 |
| | |