| 2018-12-28 09:11:47 | 1ST REVIEW: |
| | 2017 FLORIDA BUILDING CODE 6TH EDITION |
| | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION |
| | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH |
| | EDITION |
| | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION |
| | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION |
| | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH |
| | EDITION |
| | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH |
| | EDITION |
| | |
| | PLUMBING COMMENTS: |
| | |
| | 1. THE BRANCH DRAIN FOR THE WATER FOUNTAIN SHALL |
| | CONNECT TO THE BUILDING DRAIN DOWN STREAM OF THE |
| | BATHROOM GROUP. PER FBC PL 912.1 |
| | |
| | 2.PLEASE PLACE A NOTE ON THE PLAN A SEPARATE PERMIT IS |
| | REQUIRED FOR DEVICE BACKFLOW AT THE METER. CITY OF WEST |
| | PAL BEACH UTILITIES DEPT |
| | |
| | 3. PROVIDE ROOF DRAIN CALCULATIONS TO SHOW COMPLIANCE |
| | WITH FBC PL 1106.2 |
| | |
| | 4. SHT. A-400 DETAIL #2 SHOWS THE GRAB BAR 36" MEASURED |
| | TO THE CENTER OF THE BAR THIS IS NOT CODE COMPLIANT, |
| | GRAB BARS SHALL BE 33 INCHES MINIMUM AND 36 INCHES |
| | MAXIMUM ABOVE THE FINISH FLOOR MEASURED TO THETOP OF |
| | THE GRIPPING SURFACE. PER FBC ACC 609.4 |
| | |
| | 5. SHT. A-400 THE OUTLET OF THE TOILET PAPER DISPENSER |
| | SHALL BE 15 INCHES MINIMUM AND 48 INCHES MAXIMUM ABOVE |
| | THE FINISH FLOOR. FBC ACC 604.7 |
| | |
| | 6.SHT. A-400 THERE ARE TWO DETAIL #2 PLEASE CLARIFY THE |
| | ONE LABEL ENLARGED RESTROOM PLAN IS TO CONGESTED PLEASE |
| | PROVIDE A DETAIL SHOW CLEARLY THE CLEAR FLOOR SPACE |
| | WITH DIMENSIONS FOR THE TOILET AND LAVATORY. PER FBC |
| | ACC 604.3.1, 606.2 |
| | |
| | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT |
| | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID |
| | THE PREVIOUSLY REVIEWED SHEETS. |
| | |