Plan Review Notes
Plan Review Notes For Permit 18101322
Permit Number 18101322
Review Stop B
Sequence Number 2
Notes
Date Text
2018-11-29 09:20:10BUILDING REVIEW APPROVED WITH PROVISO:
 1- SEE RED-LINED NOTES ON INSTALLATION SCHEDULE. USE
 SMALLEST EFFECTIVE AREA FOR THE OPENING DESIGN
 PRESSURES CALCULATIONS.
  
 2- USE CONCRETE BLOCK ANCHOR SCHEDULE FOR SILL ANCHORS
 UNLESS CONTRACTOR PROVES POURED CONCRETE.
 8" SPACING A SHOWN ON INSTALLATION SCHEDULE IS OK FOR
 CONCRETE BLOCK INSTALLATION BASED ON THE REDUCTION
 REQUIRED BY THE EDGE DISTANCE SPECIFIED.
 (SEE EDGE DISTANCE VERSUS SPACING SCHEDULE FOR ANCHORS
 TABLE ON SHEET 13 OF 20 OF SHUTTERS DRAWINGS).