| 2019-01-22 17:03:40 | 2ND REVIEW: |
| | 2017 FLORIDA BUILDING CODE 6TH EDITION |
| | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION |
| | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH |
| | EDITION |
| | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION |
| | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION |
| | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH |
| | EDITION |
| | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH |
| | EDITION |
| | |
| | PLUMBING COMMENTS: PREVIOUS COMMENTS NOT ADDRESSED |
| | THERE ARE MAJOR DESIGN FLAWS IN THIS PLAN I I'M |
| | REQUESTING A MEETING WITH THE DESIGN PROFESSIONAL TO GO |
| | OVER COMMENTS. SEE CONTACT INFO BELOW. |
| | |
| | 1. THE SANITARY FROM THE NEW BATHROOM SHALL NOT |
| | DISCHARGE TO THE RECLAIMED WATER SYSTEM IT SHALL |
| | DISCHARGE DIRECTLY TO CITY SEWER. PER FBC PL 301.3 |
| | |
| | 2.THE NEW BATHROOM FIXTURE SHALL BE CONNECTED TOGETHER |
| | AND VENTED BY THE LAVATORY. PER FBC PL 912.1 |
| | |
| | 3. PLEASE SHOW CITY SEWER ON SITE PLAN. PER WPB AMEND |
| | TO FBC 107.2.1 |
| | |
| | 4. A TRAP PRIMER IS REQUIRED ON ANY NEW FLOOR DRAINS. |
| | PER FBC PL 1002.4.1 |
| | |
| | 5. TEMPERED WATER SHALL BE DELIVERED FROM LAVATORIES |
| | AND GROUP WASH FIXTURES LOCATED IN PUBLIC TOILET |
| | FACILITIES PROVIDED FOR CUSTOMERS, PATRONS AND |
| | VISITORS. TEMPERED WATER SHALL BE DELIVERED THROUGH AN |
| | APPROVED WATER-TEMPERATURE LIMITING DEVICE THAT |
| | CONFORMS TO ASSE 1070 OR CSA B125.3. |
| | PER FBC PL 416.5 |
| | |
| | 6. PROVIDE WATER ISOMETRIC OF NEW BATHROOM INCLUDING |
| | WATER HEATER . PER WPB AMEND TO FBC 107.3.5.1.3(13) |
| | |
| | 7. SHOW LOCATION OF WATER HEATER ON THE FLOOR PLAN. PER |
| | WPB AMEND TO FBC 107.2.1 |
| | |
| | 8. PROVIDE MANUFACTURE SPECIFICATIONS AND INSTILLATION |
| | GUIDE FOR THE WATER HEATER IT SHALL COMPLY WITH FBC |
| | ENERGY TABLE 404.2 |
| | |
| | 9. THE SITE PLAN SHOWS A PROPOSED WATER METER LOCATION |
| | IF THEY ARE INSTALLING A NEW METER A NEW BACKFLOW WILL |
| | BE REQUIRED PLEASE PLACE NOTE ON PLAN A SEPARATE PERMIT |
| | WILL BE REQUIRED FOR THE NEW BACKFLOW. PER WPB |
| | UTILITIES DEPT. |
| | |
| | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT |
| | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID |
| | THE PREVIOUSLY REVIEWED SHEETS. |
| | |