| 2018-12-11 13:44:48 | CODES IN EFFECT: |
| | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION |
| | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 |
| | 6TH ED, CHAPTER 1. |
| | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 |
| | 6TH EDITION |
| | FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION |
| | FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION |
| | FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH |
| | EDITION |
| | FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION |
| | FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION |
| | FAC= FLORIDA ADMINISTRATIVE CODE |
| | FS = FLORIDA STATUTES |
| | |
| | 1ST REVIEW: DENIED |
| | 1. R: WATER HEATER DETAIL, SHOW THERMAL EXPANSION |
| | RELIEF COMPLYING WITH THE REQUIREMENTS OF FBC PL 607.3 |
| | 2. MASTER BATH LAVATORY AND NEW BATH LAVATORY EACH |
| | REQUIRS A VENT. PROVIDE INDIVIDUAL VENT OR AIR |
| | ADMITTANCE VALVE IN ACCORDANCE WITH P3106.1 AND |
| | P3104.1. |
| | 3. THE VENT CONNECTED TO THE NEW BATH TUB FIXTURE DRAIN |
| | SHALL NOT TRAVEL HORIZONTALLY. IT MUST RISE VERTICALLY |
| | TO A POINT 6? ABOVE THE FIXTURE FLOOD LEVEL RIM BEFORE |
| | OFFSETTING HORIZONTALLY. SEE P3104.3 AND P3104. |
| | |
| | END OF COMMENTS |
| | |
| | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN |
| | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES |
| | (STAMPED/SEALED AND SIGNED BY DESIGNER OF RECORD IN |
| | ACCORDANCE WITH FS 471 FAC 61G15) INTO THE ORIGINAL |
| | SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS. |
| | ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD |
| | REMAIN IN PACKAGE AND BE MARKED "VOID". |
| | |