| 2019-01-19 10:45:43 | ****CORRECTIONS**** | | | | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | FBC 107. PLEASE PROVIDE MORE INFORMATION: | | | | | | THE PENDING ITEMS FROM LAST REVIEW CONTINUE AS NOTED | | | BELOW: | | | | | | 1. VALUATION: THE VALUATION SHOWN ON THE APPLICATION | | | SHOULD BE A TOTAL AND NEEDS TO INCLUDE VALUE OF RELATED | | | SUB PERMITS. | | | | | | 2. THE TIE BEAM DIMENSIONS ARE NOT INCLUDED ON THE | | | LATEST SUBMITTED PLAN. ON THE INITIAL PLAN SUBMITTAL AN | | | 8" X 12" TIE BEAM WAS SHOWN BUT THERE WAS ALSO A DETAIL | | | FOR AN 8" X 8" BOND BEAM. PLEASE CLARIFY. | | | | | | 3. THE WINDOW SCHEDULE IDENTIFICATION "MARKS" DO NOT | | | MATCH THE IDENTIFACATION NUMBERS SHOWN ON THE OPENINGS | | | OF THE FLOOR PLAN. | | | | | | 4. PLEASE PROVIDE A CONNECTOR SCHEDULE FOR THE ROOF | | | TRUSS TO THE TIE BEAM. THE SCHEDULE NEEDS TO INCLUDE | | | THE SPECIFIC CONNECTORS TO BE USED AND NUMBER/SIZE OF | | | FASTENERS. | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL COMMENTS MAY | | | RESULT IN NEW PLAN REVIEW COMMENTS. |
|