| Plan Review Notes For Permit 18100795 |
| Permit Number |
18100795 |
|
| Review Stop |
P |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2018-12-06 13:41:10 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION | | | FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH | | | EDITION | | | FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION | | | FAC= FLORIDA ADMINISTRATIVE CODE | | | FS = FLORIDA STATUTES | | | | | | 1ST REVIEW: DENIED | | | 1. THE DISHWASHER DISCHARGE PIPE OR TUBING SHALL RISE | | | TO THE UNDERSIDE OF THE COUNTER AND BE FASTENED OR | | | OTHERWISE HELD IN THAT POSITION BEFORE CONNECTING TO | | | THE HEAD OF THE FOOD-WASTE DISPOSER OR TO A WYE FITTING | | | IN THE SINK TAILPIECE NOT DOWNSTREAM OF THE TRAP PER | | | FBC RES P2717.2. | | | 2. ICE MAKER AND REFRIGERATOR/FREEZER DISCHARGES SHALL | | | NOT BE CONNECTED DIRECTLY TO THE SANITARY. PROVIDE | | | INDIRECT WASTE THROUGH AN AIR GAP TO A TRAPPED AND | | | VENTED WASTE RECEPTOR SUCH AS A HUB DRAIN OR FLOOR SINK | | | IN ACCORDANCE WITH FBC RES P2706 AND FBC PL 802.2. | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | PHONE 561-805-6715 | | | |
|