2018-12-06 13:41:10CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH
 EDITION
 FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
 1ST REVIEW: DENIED
 1. THE DISHWASHER DISCHARGE PIPE OR TUBING SHALL RISE
 TO THE UNDERSIDE OF THE COUNTER AND BE FASTENED OR
 OTHERWISE HELD IN THAT POSITION BEFORE CONNECTING TO
 THE HEAD OF THE FOOD-WASTE DISPOSER OR TO A WYE FITTING
 IN THE SINK TAILPIECE NOT DOWNSTREAM OF THE TRAP PER
 FBC RES P2717.2.
 2. ICE MAKER AND REFRIGERATOR/FREEZER DISCHARGES SHALL
 NOT BE CONNECTED DIRECTLY TO THE SANITARY. PROVIDE
 INDIRECT WASTE THROUGH AN AIR GAP TO A TRAPPED AND
 VENTED WASTE RECEPTOR SUCH AS A HUB DRAIN OR FLOOR SINK
 IN ACCORDANCE WITH FBC RES P2706 AND FBC PL 802.2.
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 PHONE 561-805-6715
  