| Plan Review Notes For Permit 18100775 |
| Permit Number |
18100775 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2018-10-17 15:42:47 | RESIDENTIAL (R3) RE-ROOF BUILDING REVIEW COMMENTS | | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | | | | | 1- FLAT ROOF NOA 17-1003.04 SUBMITTED; PROVIDE SIGNED | | | AND SEALED RAS 117 CALCULATIONS FOR PERIMETER AND | | | CORNER AREAS AS REQUIRED BY GENERAL LIMITATION #7 ON | | | LAST PAGE OF NOA SUBMITTED. NEED RAS 117 CALCULATIONS | | | TO MEET THE DESIGN PRESSURES OF EACH ROOF ZONE AS | | | REQUIRED BY SEC. R301.1 FBC-RESIDENTIAL. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | |
|