| Plan Review Notes For Permit 18100654 |
| Permit Number |
18100654 |
|
| Review Stop |
M |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2019-01-02 14:34:49 | MECHANICAL PLAN REVIEW PASS WITH PROVISO (SEE PLANS) | | | | | | R303.10REQUIRED HEATING.WHERE THE WINTER DESIGN | | | TEMPERATURE IN TABLE R301.2(1) IS BELOW 60?F (16?C), | | | EVERY DWELLING UNIT SHALL BE PROVIDED WITH HEATING | | | FACILITIES CAPABLE OF MAINTAINING A ROOM TEMPERATURE OF | | | NOT LESS THAN 68?F (20?C) AT A POINT 3 FEET (914 MM) | | | ABOVE THE FLOOR AND 2 FEET (610 MM) FROM EXTERIOR WALLS | | | IN HABITABLE ROOMS AT THE DESIGN TEMPERATURE. THE | | | INSTALLATION OF ONE OR MORE PORTABLE SPACE HEATERS | | | SHALL NOT BE USED TO ACHIEVE COMPLIANCE WITH THIS | | | SECTION. | | | | | | | | | CHRIS MONTELLO | | | 561-503-3556 | | | [email protected] |
|