2020-09-23 09:09:21THE PROPERTY IS LOCATED IN AN AE FLOOD ZONE WITH A BASE
 FLOOD ELEVATION OF 7' NAVD88. THE CITY'S FLOOD
 ORDINANCE REQUIRES A 2' FREEBOARD WHICH MAKES THE
 DESIGN FLOOD ELEVATION FOR THIS PROJECT 9.0'. ALL
 EQUIPMENT SERVICING THE BUILDING IS REQUIRED TO BE AT
 OR ABOVE 9' NAVD. ELEVATION CERTIFICATES WILL BE
 REQUIRED TO SHOW COMPLIANCE WITH THE CITY'S FLOOD
 POLICY. THE CITY REQUIRES THREE ELEVATION CERTIFICATES.
 FIRST, A PRECONSTRUCTION ELEV. CERT. BASED ON THE
 CONSTRUCTION DRAWING. SECOND, A CONSTRUCTION ELEV.
 CERT. BASED ON THE LOWEST FLOOR FORMS. THIRD A FINAL
 ELEV. CERT. BASED ON THE FINISHED BUILDING. PLEASE
 SUBMIT THE PRECONSTRUCTION ELEVATION CERTIFICATE AT
 THIS TIME. THE CITY'S FLOOD ORDINANCE ARTICLE XVII -
 FLOOD PREVENTION AND CONTROL SEC. 94-546 - PROVISIONS
 FOR FLOOD HAZARD REDUCTION.
 NOTE: THE PRECONSTRUCTION ELEVATION THAT WAS SUBMITTED
 HAS ERRORS AND A CORRECTED ONE IS REQUIRED BEFORE THE
 PERMIT TO BEGIN VERTICAL CONSTRUCTION IS ISSUED. THE
 BASE FLOOD ELEVATION IS 6' ON THE FORM AND IT SHOULD BE
 7' NAVD 88. THERE IS AN ATTACHED GARAGE WITH AN
 ELEVATION OF 9.0' NAVD 88.