Notes
Date Text
2018-12-05 09:04:51PROVISO:
 1. THE LAVATORY SINKS IN THE BATHROOM SHALL SUPPLY
 TEMPERED WATER ONLY THROUGH A TEMPERATURE LIMITING
 DEVICE THAT COMPLIES WITH ASSE 1070 OR CSA B125.3. THE
 MIXING VALVE ON THE WHOLE HOT WATER SYSTEM DOES NOT
 COMPLY WITH ASSE 1070 OR CSA B125.3 SHALL COMPLY WITH
 FBC PL 416.5
 2. A HOT WATER RECIRCULATION SYSTEM IS REQUIRED FOR THE
 BAR SINK IT IS SHOWN ON THE WATER HEATER DETAIL ON
 SHT.P0.1 BUT IS NOT SHOWN ON THE FLOOR PLAN OR THE
 WATER ISOMETRIC. SHALL COMPLY WITH FBC PL 607.2
  
  