Plan Review Notes
Plan Review Notes For Permit 18100316
Permit Number 18100316
Review Stop B
Sequence Number 2
Notes
Date Text
2018-10-16 18:52:50RESIDENTIAL (R2) BUILDING REVIEW COMMENTS
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
  
 ORIGINAL COMMENT:
 1- PROVIDE SHUTTERS COMPLETE INSTALLATION SCHEDULE AS
 REQUIRED BY CITY IMPLEMENTATION STANDARD FOR WIND-BORNE
 DEBRIS IMPACT PROTECTION FOR THE FLORIDA BUILDING CODE.
 SEE CITY SAMPLE. ALL THE COLUMNS NEED TO BE COMPLETED.
 ALTERNATIVELY, YOU MAY PROVIDE COMPLETE INSTALLATION
 SCHEDULE IN ANY OTHER FORMAT AS LONG AS ALL THE
 REQUIRED INFORMATION IS PROVIDED.
  
 RESPONSE:
 A) ACCORDING TO DESIGN PRESSURES HIGHLIGHTED ON
 ENGINEER CALCULATIONS THE ANCHOR SPACING FOR TOP
 CONNECTION IS 5.5" FOR TYPE OF ANCHOR SPECIFIED NOT
 6.5". AND THE ANCHOR SPACING FOR BOTTOM CONNECTION IS
 4" NOT 7.5". REVISE AS REQUIRED BY THE PRODUCT APPROVAL
 SUBMITTED.
 SEC. 107.2.1 CITY AMENDMENTS.
  
 B) CLEARLY SPECIFY THE MINIMUM EDGE DISTANCE AS
 REQUIRED BY INSTALLATION DETAILS "G" AND "J" ON PRODUCT
 APPROVAL SUBMITTED. CLARIFY WHAT IS EDGE DISTANCE
 "TRAPPED" AS SPECIFIED ON THE SHUTTER INSTALLATION
 SCHEDULE SUBMITTED?.
 SEC. 107.2.1 CITY AMENDMENTS.
  
 ORIGINAL COMMENT:
 2- ENGINEER CALCULATIONS SUBMITTED NEED TO HAVE THE
 ORIGINAL SEAL AND SIGNATURE OF THE ENGINEER OF RECORD
 AS REQUIRED BY SEC. 61G15-23.003 FAC AND CHAPTER 471
 F.S. WHEN SUBMITTING PLANS/DOCUMENTS FOR PUBLIC
 RECORDS.
  
 RESPONSE:
 REPEAT COMMENT. NOT ADDRESSED.
  
  