| Date |
Text |
| 2018-11-06 10:57:05 | CODES IN EFFECT: |
| | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION |
| | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 |
| | 6TH ED, CHAPTER 1. |
| | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 |
| | 6TH EDITION |
| | FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION |
| | FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION |
| | FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH |
| | EDITION |
| | FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION |
| | FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION |
| | FAC= FLORIDA ADMINISTRATIVE CODE |
| | FS = FLORIDA STATUTES |
| | |
| | 1ST REVIEW |
| | PLUMBING COMMENTS: DENIED |
| | |
| | 1. DUE TO THE COMPLEXITY OF THE PROJECT, THE PLUMBING |
| | PIPING PLAN REQUIRES MORE INFORMATION. PROVIDE 1ST AND |
| | 2ND FLOOR PLAN PLUMBING LAYOUT IN PLAN VIEW. SHOW WHICH |
| | WALLS THE SANITARY RISERS TO THE SECOND FLOOR WILL BE |
| | LOCATED. PLAN VIEWS AND RISER DIAGRAM SHALL MATCH. WPB |
| | FBC 107.2.1 |
| | 2. RE: PLAN SHEET A10; SANITARY RISER DIAGRAM |
| | A. PLEASE PROVIDE A DIRECTIONAL ORIENTATION SO THAT THE |
| | DIAGRAM CORRESPONDS WITH THE PLAN VIEW. WPB FPC 107.2.1 |
| | B. PLEASE IDENTIFY BATHROOMS. WPB FBC 107.2.1 |
| | C. PROVIDE INDIVIDUAL VENT FOR CLOTHES WASHER FIXTURE |
| | DRAIN.FBC RES P3102.2.1 |
| | D. LAVATORY FIXTURE DRAINS IN BATH #4 CLOSEST TO THE |
| | WATER CLOSET, THE MASTER BATH AND BOTH HALF BATHS DROP |
| | VERTICALLY BEFORE CONNECTING TO THE VENT. THE TOTAL |
| | FALL IN A FIXTURE DRAIN DUE TO PIPE SLOPE SHALL NOT |
| | EXCEED THE DIAMETER OF THE FIXTURE DRAIN, NOR SHALL THE |
| | VENT CONNECTION TO A FIXTURE DRAIN, EXCEPT FOR WATER |
| | CLOSETS, BE BELOW THE WEIR OF THE TRAP PER FBC RES |
| | P3105.2. CORRECT AND RESUBMIT |
| | E. A LAVATORY IN THE MASTER BATH IS NOT SHOWN. INCLUDE |
| | ON RESUBMITTED DIAGRAM. WPB FBC 107.2.1 |
| | |
| | END OF COMMENTS. |
| | |
| | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN |
| | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES |
| | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY |
| | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED |
| | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD |
| | SHEETS. |
| | |
| | |
| | JERALD SMITH |
| | PLUMBING PLANS EXAMINER |
| | EMAIL: [email protected] |
| | PHONE: 561-805-6715 |
| | |