2019-01-30 10:52:11RESIDENTIAL (R3) ADDITION SECOND BUILDING REVIEW
 CHECKLIST.
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
  
 NOTE:
 BUILDING REVIEW MAY BE APPROVED WITH PROVISO. PROVISO
 MEANS CONTRACTOR WILL SUBMIT REQUIRED INFORMATION AFTER
 THE PERMIT IS ISSUED BUT BEFORE INSPECTIONS TO AVOID
 CONFLICTS/DELAYS. REVISION FEES MAY APPLY. CONTRACTOR
 TO ADVICE IF PROVISO OPTION IS PREFERRED AT THIS TIME
 OR IF RE-SUBMITTING REQUIRED INFORMATION BEFORE PERMIT
 ISSUANCE. (NOTE: ALL DRAWINGS NEED TO HAVE THE
 ENGINEER'S SEAL PRIOR TO ISSUANCE OF PERMIT)
  
  
  
  
 1- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 FAC 61G20-3.001 FOR:
 (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED
 SUBMITTAL)
  
 ORIGINAL COMMENT:
 FLAT ROOF NOA 17-0222.09 SUBMITTED; CLEARLY MARK
 SPECIFIC ASSEMBLY TO BE INSTALLED AND PROVIDE SIGNED
 AND SEALED RAS 117 CALCULATIONS FOR PERIMETER AND
 CORNER AREAS AS REQUIRED BY GENERAL LIMITATION #7 ON
 LAST PAGE OF NOA SUBMITTED. NEED RAS 117 CALCULATIONS
 TO MEET THE DESIGN PRESSURES OF EACH ROOF ZONE AS
 REQUIRED BY SEC. R301.1 FBC-RESIDENTIAL.
  
 RESPONSE:
 ENGINEER RAS 117 CALCULATIONS SUBMITTED NEED TO BE
 REVISED:
 A) REVISE THE PARAMETERS CRITERIA:
 (1)THE BUILDING EXPOSURE IS "C" NOT "B". SEE SEC.
 R301.2.1.4 FBC-RESIDENTIAL.
  
 (2)THE RISK CATEGORY IS 2 NOT 1. SEE TABLE 1604.5 FBC.
  
 B)APPROVED ASSEMBLY FROM NOA 17-0222.09 IS NOT
 IDENTIFIED ON THE CALCULATION. SEC. R301.1
 FBC-RESIDENTIAL.
  
 C) FRONT PAGE CALLS FOR "CERTAINTEED MODIFIED BITUMEN
 ROOFING SYSTEM". NOA SUBMITTED IS FOR "TAMKO MODIFIED
 BITUMEN ROOFING SYSTEM" NOT CERTAINTEED. REVISE AS
 REQUIRED TO MATCH NOA SUBMITTED. SEC. 107.2.1 CITY
 AMENDMENTS.
  
 D) FASTENER DENSITIES SPECIFIED FOR ROOF ZONE #1 (FIELD
 ZONE) DON'T CORRESPOND TO FASTENER DENSITIES SHOWN ON
 PRODUCT APPROVAL SUBMITTED.
  
 E) CLEARLY SPECIFY FASTENER TYPE AND SPACING FOR EACH
 ROOF ZONE, INCLUDING NUMBER OF ROWS IN THE CENTER OF
 THE SHEET. SEC. R301.1 FBC-RESIDENTIAL.
  
 2- NEW COMMENTS:
 DETAIL "E" ON SHEET S1 IS INCOMPLETE. NEED TO SPECIFY:
 (1)SIZE AND THICKNESS OF "SPECIAL HANGER".
  
 (2) WELDING SPECIFICATIONS. NOTE: INCLUDE WELDING
 SPECIFICATIONS AT BOTTOM OF COLUMN.
  
 (3) SPECIFICATIONS FOR CONNECTION OF WOOD BEAM TO
 SPECIAL CONNECTOR.
  
  
 3- ONE SET OF PLANS IS MISSING THE ENGINEER'S SEAL ON
 DRAWINGS S1, EX2 AND EX3 AS REQUIRED BY CHAPTER 471
 F.S.
  
  
 ARCHITECTS-ENGINEERS
 FLORIDA STATUTE 553.80(2)(B):
 WITH RESPECT TO EVALUATION OF DESIGN PROFESSIONALS
 DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT NECESSARY, IN
 ORDER TO ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING
 CODE AND ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS
 REQUIRED BY THE CODE THREE OR MORE TIMES FOR FAILURE TO
 CORRECT A CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY
 NOTED IN EACH REJECTION, INCLUDING, BUT NOT LIMITED TO,
 EGRESS, FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY,
 ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL,
 MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER
 REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING
 COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL
 GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH
 REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION,
 A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE
 PERMIT FEE ATTRIBUTED TO PLANS REVIEW
  
  
  
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE/VOID THE
 PREVIOUSLY REVIEWED SHEETS.
 PLEASE DON'T STAPLE OLD DRAWINGS. SUBMIT OLD DRAWINGS
 FOR REFERENCE.
  