| 2019-01-30 10:52:11 | RESIDENTIAL (R3) ADDITION SECOND BUILDING REVIEW |
| | CHECKLIST. |
| | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. |
| | |
| | NOTE: |
| | BUILDING REVIEW MAY BE APPROVED WITH PROVISO. PROVISO |
| | MEANS CONTRACTOR WILL SUBMIT REQUIRED INFORMATION AFTER |
| | THE PERMIT IS ISSUED BUT BEFORE INSPECTIONS TO AVOID |
| | CONFLICTS/DELAYS. REVISION FEES MAY APPLY. CONTRACTOR |
| | TO ADVICE IF PROVISO OPTION IS PREFERRED AT THIS TIME |
| | OR IF RE-SUBMITTING REQUIRED INFORMATION BEFORE PERMIT |
| | ISSUANCE. (NOTE: ALL DRAWINGS NEED TO HAVE THE |
| | ENGINEER'S SEAL PRIOR TO ISSUANCE OF PERMIT) |
| | |
| | |
| | |
| | |
| | 1- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY |
| | FAC 61G20-3.001 FOR: |
| | (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED |
| | SUBMITTAL) |
| | |
| | ORIGINAL COMMENT: |
| | FLAT ROOF NOA 17-0222.09 SUBMITTED; CLEARLY MARK |
| | SPECIFIC ASSEMBLY TO BE INSTALLED AND PROVIDE SIGNED |
| | AND SEALED RAS 117 CALCULATIONS FOR PERIMETER AND |
| | CORNER AREAS AS REQUIRED BY GENERAL LIMITATION #7 ON |
| | LAST PAGE OF NOA SUBMITTED. NEED RAS 117 CALCULATIONS |
| | TO MEET THE DESIGN PRESSURES OF EACH ROOF ZONE AS |
| | REQUIRED BY SEC. R301.1 FBC-RESIDENTIAL. |
| | |
| | RESPONSE: |
| | ENGINEER RAS 117 CALCULATIONS SUBMITTED NEED TO BE |
| | REVISED: |
| | A) REVISE THE PARAMETERS CRITERIA: |
| | (1)THE BUILDING EXPOSURE IS "C" NOT "B". SEE SEC. |
| | R301.2.1.4 FBC-RESIDENTIAL. |
| | |
| | (2)THE RISK CATEGORY IS 2 NOT 1. SEE TABLE 1604.5 FBC. |
| | |
| | B)APPROVED ASSEMBLY FROM NOA 17-0222.09 IS NOT |
| | IDENTIFIED ON THE CALCULATION. SEC. R301.1 |
| | FBC-RESIDENTIAL. |
| | |
| | C) FRONT PAGE CALLS FOR "CERTAINTEED MODIFIED BITUMEN |
| | ROOFING SYSTEM". NOA SUBMITTED IS FOR "TAMKO MODIFIED |
| | BITUMEN ROOFING SYSTEM" NOT CERTAINTEED. REVISE AS |
| | REQUIRED TO MATCH NOA SUBMITTED. SEC. 107.2.1 CITY |
| | AMENDMENTS. |
| | |
| | D) FASTENER DENSITIES SPECIFIED FOR ROOF ZONE #1 (FIELD |
| | ZONE) DON'T CORRESPOND TO FASTENER DENSITIES SHOWN ON |
| | PRODUCT APPROVAL SUBMITTED. |
| | |
| | E) CLEARLY SPECIFY FASTENER TYPE AND SPACING FOR EACH |
| | ROOF ZONE, INCLUDING NUMBER OF ROWS IN THE CENTER OF |
| | THE SHEET. SEC. R301.1 FBC-RESIDENTIAL. |
| | |
| | 2- NEW COMMENTS: |
| | DETAIL "E" ON SHEET S1 IS INCOMPLETE. NEED TO SPECIFY: |
| | (1)SIZE AND THICKNESS OF "SPECIAL HANGER". |
| | |
| | (2) WELDING SPECIFICATIONS. NOTE: INCLUDE WELDING |
| | SPECIFICATIONS AT BOTTOM OF COLUMN. |
| | |
| | (3) SPECIFICATIONS FOR CONNECTION OF WOOD BEAM TO |
| | SPECIAL CONNECTOR. |
| | |
| | |
| | 3- ONE SET OF PLANS IS MISSING THE ENGINEER'S SEAL ON |
| | DRAWINGS S1, EX2 AND EX3 AS REQUIRED BY CHAPTER 471 |
| | F.S. |
| | |
| | |
| | ARCHITECTS-ENGINEERS |
| | FLORIDA STATUTE 553.80(2)(B): |
| | WITH RESPECT TO EVALUATION OF DESIGN PROFESSIONALS |
| | DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT NECESSARY, IN |
| | ORDER TO ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING |
| | CODE AND ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS |
| | REQUIRED BY THE CODE THREE OR MORE TIMES FOR FAILURE TO |
| | CORRECT A CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY |
| | NOTED IN EACH REJECTION, INCLUDING, BUT NOT LIMITED TO, |
| | EGRESS, FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY, |
| | ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL, |
| | MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER |
| | REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING |
| | COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL |
| | GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH |
| | REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION, |
| | A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE |
| | PERMIT FEE ATTRIBUTED TO PLANS REVIEW |
| | |
| | |
| | |
| | |
| | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT |
| | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE/VOID THE |
| | PREVIOUSLY REVIEWED SHEETS. |
| | PLEASE DON'T STAPLE OLD DRAWINGS. SUBMIT OLD DRAWINGS |
| | FOR REFERENCE. |
| | |
| | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT |
| | JULIO GOMEZ |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | BUILDING DIVISION |
| | (561)805-6712 |
| | [email protected] |
| | |