| Plan Review Notes For Permit 18091117 |
| Permit Number |
18091117 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2018-10-18 10:20:02 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC SIXTH EDITION (2017) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) SUBMIT TWO SETS OF SIGNED AND SEALED DRAWINGS. | | | PURSUANT TO FBC 107.1, THE DESIGN MUST BE PREPARED BY A | | | PROFESSIONAL LICENSED PURSUANT TO FS 471. SEE BELOW: | | | FBC107.1 GENERAL. SUBMITTAL DOCUMENTS CONSISTING OF | | | CONSTRUCTION DOCUMENTS, STATEMENT OF SPECIAL | | | INSPECTIONS, GEOTECHNICAL REPORT AND OTHER DATA SHALL | | | BE SUBMITTED IN TWO OR MORE SETS WITH EACH PERMIT | | | APPLICATION. THE CONSTRUCTION DOCUMENTS SHALL BE | | | PREPARED BY A REGISTERED DESIGN PROFESSIONAL WHERE | | | REQUIRED BY CHAPTER 471, FLORIDA STATUTES & 61G15 | | | FLORIDA ADMINISTRATIVE CODE. WHERE SPECIAL CONDITIONS | | | EXIST, THE BUILDING OFFICIAL IS AUTHORIZED TO REQUIRE | | | ADDITIONAL CONSTRUCTION DOCUMENTS TO BE PREPARED BY A | | | REGISTERED DESIGN PROFESSIONAL. | | | | | | 2) PROVIDE DETAILS, DIMENSIONS, BOTTOM SLOPE, SWIMOUTS, | | | ETC. TO SHOW THAT THE PROPOSED POOL COMPLIES WITH THE | | | REQUIREMENTS OF FBC-R 4501.6 AND ANSI/APSP/ICC 5 - 11. | | | | | | 3) SUBMIT TWO SETS THE MANUFACTURER'S INSTALLATION | | | INSTRUCTIONS AND LISTING FOR THE PROPOSED POOL BARRIER | | | FENCE. FBC-R 4501.17 |
|