| 2018-11-01 14:15:59 | BUILDING PLAN REVIEW |
| | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST |
| | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, |
| | CHAPTER 1 ADMINISTRATION |
| | |
| | CHRISTOPHER S. THROOP, C.B.O. |
| | PLANS EXAMINER, PX3169 |
| | CONSTRUCTION SERVICES DIVISION |
| | TEL: 561-805-6726 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | 1ST REVIEW |
| | RESULTS: DENIED |
| | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED |
| | BELOW. |
| | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| | |
| | 1. ROOF FRAMING - PROPOSED ROOF INDICATES A |
| | PRE-ENGINEERED ROOF SYSTEM. DETAIL - TYP.RIDGE COPING |
| | DETAIL ON PLAN PAGE A-4 INDICATES A RIDGE BEAM AND |
| | RAFTER SYSTEM. PLEASE CLARIFY. |
| | 2. WALL INSULATION - ENERGY SUBMITTAL REQUIRES R-19. |
| | PLANS INDICATE R-15. PLEASE CLARIFY. |
| | 3. CRAWL SPACE INSULATION - ENERGY SUBMITTAL REQUIRED |
| | R-19. PLANS SHOW NO INSULATION IN CRAWL SPACE. PLEASE |
| | CLARIFY. |
| | 4. PROVIDE CRAWL SPACE VENTS PER R408.1 AND ACCESS PER |
| | R408.4. |
| | 5. EGRESS WINDOW - PGT-700 SERIES. WINDOW SIZE FROM |
| | WINDOW SCHEDULE 3' X 5' DOES NOT PROVIDE THE REQUIRED |
| | EGRESS OPENING PER R310.2.1. SELECT WINDOW FROM PGT |
| | CATALOG THAT MEETS EGRESS REQUIREMENTS. CHANGE ROUGH |
| | OPENING DEMENSIONS FOR NEW WINDOW. |
| | |
| | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT |
| | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY |
| | REVIEWED SHEETS DETACHED. |
| | |
| | |