| Date |
Text |
| 2018-09-18 10:47:45 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE |
| | MARSHAL, WITH THE FOLLOWING COMMENTS: |
| | |
| | |
| | 1) SHEET A 2 - THERE IS AN INDICATION OF AN AREA OF |
| | REFUGE AND SEE SHEET A 2.1 FOR MORE INFORMATION. THERE |
| | IS NO SHEET A 2.1. |
| | |
| | PLEASE VIEW AND CORRECT OR JUSTIFY. |
| | |
| | |
| | |
| | 2) SHEET A 2 - THERE IS AN INDICATION OF THE NUMBER OF |
| | EXITS AS 2; HOWEVER, THERE IS ONLY ONE EXIT SHOWN ON |
| | THE PLAN DRAWING. |
| | |
| | PER NFPA 101, 2 EXITS ARE REQUIRED. |
| | |
| | 39.2.4 NUMBER OF MEANS OF EGRESS. |
| | 39.2.4.1 MEANS OF EGRESS SHALL COMPLY WITH ALL OF THE |
| | FOLLOWING, |
| | EXCEPT AS OTHERWISE PERMITTED BY 39.2.4.2 THROUGH |
| | 39.2.4.6: |
| | (1) THE NUMBER OF MEANS OF EGRESS SHALL BE IN |
| | ACCORDANCE WITH |
| | 7.4.1.1 AND 7.4.1.3 THROUGH 7.4.1.6. |
| | (2) NOT LESS THAN TWO SEPARATE EXITS SHALL BE PROVIDED |
| | ON EVERY |
| | STORY. |
| | (3) NOT LESS THAN TWO SEPARATE EXITS SHALL BE |
| | ACCESSIBLE FROM |
| | EVERY PART OF EVERY STORY. |
| | |
| | PLEASE PROVIDE THE 2ND EXIT PLAN DRAWING. |
| | |
| | |
| | |
| | |
| | 3) SHEET A 2 & E - THERE IS AN INDICATION OF THE |
| | INSTALLATION OF A VOICE EVACUATION ALARM AND E SHEETS |
| | DO NOT SHOW ANY DEVICES . |
| | |
| | ANY WORK ON A FIRE ALARM SYSTEM SHALL BE UNDER SEPARATE |
| | SHOP DRAWINGS BY CERTIFIED LIFE SAFETY CONTRACOTRS. |
| | |
| | PLEASE PROVIDE THE APPLICABLE NOTE . |
| | |
| | |
| | |
| | |
| | 4) SHEET A 2 & A 3 - THERE ARE INDICATIONS OF NEW |
| | DOORS; HOWEVER, THERE IS NO INDICATION OF A DOOR |
| | SCHEDULE, INCLUDING HARDWARE & LOCKS. |
| | |
| | PLEASE PROVIDE A DOOR SCHEDULE . |
| | |
| | |
| | |
| | 5) SHEET A 4 & E 2.1 - THERE ARE INDICATIONS OF NEW |
| | CORRIDORS; HOWEVER, THERE ARE NO EXIT SIGNS INDICATED |
| | IN THE APPLICABLE AREAS. EITHER EXISTING OR NEW. |
| | |
| | PLEASE REVIEW AND CORRECT OR JUSTIFY. |
| | |
| | |
| | |
| | 6) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET |
| | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE |
| | ABOVE. |
| | |
| | |
| | |
| | 7) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE |
| | RE-SUBMITTAL OF THE ABOVE. |
| | |
| | |
| | |
| | PETER LEDUC |
| | FIRE MARSHAL |
| | 561-804-4709 |
| | [email protected] |
| | |