| Date |
Text |
| 2018-10-09 14:34:12 | CODES IN EFFECT: |
| | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION |
| | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 |
| | 6TH ED, CHAPTER 1. |
| | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 |
| | 6TH EDITION |
| | FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION |
| | FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION |
| | FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION |
| | FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION |
| | FAC= FLORIDA ADMINISTRATIVE CODE |
| | FS = FLORIDA STATUTES |
| | |
| | 1ST REVIEW: |
| | PLUMBING COMMENTS: DENIED |
| | |
| | 1. RE: LAUNDRY ROOM IN STORAGE BUILDING; PLUMBING |
| | CONTRACTOR TO PROVIDE TWO SIGNED SETS OF SANITARY |
| | ISOMETRIC DRAWING NOTING THE CLOTHES WASHER FIXTURE |
| | DRAIN, TRAP, VENT, BUILDING DRAIN AND BUILDING SEWER |
| | FROM THE STORAGE BUILDING TO THE CONNECTION WITH THE |
| | HOUSE BUILDING SEWER INCLUDING SIZING. WPB FBC 107.2.1, |
| | FS 471 & FAC 61G15 |
| | A. ALL PLUMBING WORK ABOVE AND BELOW GROUND SHALL BE |
| | TESTED AND INSPECTED FOR COMPLIANCE IN ACCORDANCE WITH |
| | WPB FPC 110.3.C. |
| | B. PROVIDE WATER HAMMER ARRESTORS AT WATER SUPPLIES TO |
| | THE CLOTHES WASHER PER FBC RES P2903.5; INDICATE SAME |
| | ON THE PLANS PER WPB FPC 107.2.1 |
| | 2. RE: BATHROOM |
| | A. A SHOWER PAN SHALL BE INSTALLED IN ACCORDANCE WITH |
| | FBC RES P2709 AND SHALL BE TESTED AND INSPECTED FOR |
| | COMPLIANCE IN ACCORDANCE WITH WPB FPC 110.3.C. |
| | B. SHOW CURB ON SHOWER PAN DETAIL IN ACCORDANCE WITH |
| | WPB FBC 107.2.1 SHOWING COMPLIANCE WITH FBC RES P2709 |
| | B. PIPING BENEATH BATHROOM FLOOR SHALL BE TESTED AND |
| | INSPECTED FOR COMPLIANCE IN ACCORDANCE WITH WPB FPC |
| | 110.3.C. |
| | C. PARTITION PIPING SHALL BE TESTED AND INSPECTED FOR |
| | COMPLIANCE IN ACCORDANCE WITH WPB FPC 110.3.C. |
| | D. SHOWER CONTROL VALVE(S) SHALL BE PRESSURE BALANCED |
| | PB,THERMOSTATIC MIXING (TM) OR COMBINATION PB/TM VALVE |
| | TYPES WITH HIGH TEMPERATURE LIMITING STOP IN ACCORDANCE |
| | WITH FBC RES 2708.4; INDICATE SAME ON THE PLANS PER WPB |
| | FPC 107.2.1. |
| | |
| | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN |
| | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES |
| | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY |
| | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED |
| | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED "VOID". |
| | |
| | |
| | JERALD SMITH |
| | PLUMBING PLANS EXAMINER |
| | CITY OF WEST PALM BEACH |
| | EMAIL [email protected] |
| | PHONE 561-805-6715 |