Plan Review Notes
Plan Review Notes For Permit 18090587
Permit Number 18090587
Review Stop P
Sequence Number 1
Notes
Date Text
2018-10-09 14:34:12CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION
 FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION
 FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
 1ST REVIEW:
 PLUMBING COMMENTS: DENIED
  
 1. RE: LAUNDRY ROOM IN STORAGE BUILDING; PLUMBING
 CONTRACTOR TO PROVIDE TWO SIGNED SETS OF SANITARY
 ISOMETRIC DRAWING NOTING THE CLOTHES WASHER FIXTURE
 DRAIN, TRAP, VENT, BUILDING DRAIN AND BUILDING SEWER
 FROM THE STORAGE BUILDING TO THE CONNECTION WITH THE
 HOUSE BUILDING SEWER INCLUDING SIZING. WPB FBC 107.2.1,
 FS 471 & FAC 61G15
 A. ALL PLUMBING WORK ABOVE AND BELOW GROUND SHALL BE
 TESTED AND INSPECTED FOR COMPLIANCE IN ACCORDANCE WITH
 WPB FPC 110.3.C.
 B. PROVIDE WATER HAMMER ARRESTORS AT WATER SUPPLIES TO
 THE CLOTHES WASHER PER FBC RES P2903.5; INDICATE SAME
 ON THE PLANS PER WPB FPC 107.2.1
 2. RE: BATHROOM
 A. A SHOWER PAN SHALL BE INSTALLED IN ACCORDANCE WITH
 FBC RES P2709 AND SHALL BE TESTED AND INSPECTED FOR
 COMPLIANCE IN ACCORDANCE WITH WPB FPC 110.3.C.
 B. SHOW CURB ON SHOWER PAN DETAIL IN ACCORDANCE WITH
 WPB FBC 107.2.1 SHOWING COMPLIANCE WITH FBC RES P2709
 B. PIPING BENEATH BATHROOM FLOOR SHALL BE TESTED AND
 INSPECTED FOR COMPLIANCE IN ACCORDANCE WITH WPB FPC
 110.3.C.
 C. PARTITION PIPING SHALL BE TESTED AND INSPECTED FOR
 COMPLIANCE IN ACCORDANCE WITH WPB FPC 110.3.C.
 D. SHOWER CONTROL VALVE(S) SHALL BE PRESSURE BALANCED
 PB,THERMOSTATIC MIXING (TM) OR COMBINATION PB/TM VALVE
 TYPES WITH HIGH TEMPERATURE LIMITING STOP IN ACCORDANCE
 WITH FBC RES 2708.4; INDICATE SAME ON THE PLANS PER WPB
 FPC 107.2.1.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY
 REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED
 SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED "VOID".
  
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 PHONE 561-805-6715


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved