| Date |
Text |
| 2018-09-12 09:44:22 | RESIDENTIAL (R3) RE-ROOF, BUILDING REVIEW COMMENTS |
| | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. |
| | |
| | 1- 1- HOUSE VALUE IS MORE THAN $300.000. NEED TO COMPLY |
| | WITH THE ROOF TO WALL CONNECTIONS AS REQUIRED BY SEC. |
| | 706.8 FBC-EXISTING-BUILDING. |
| | |
| | SEC. 706.8: |
| | WHEN A ROOF COVERING ON AN EXISTING SITE-BUILT SINGLE |
| | FAMILY RESIDENTIAL STRUCTURE IS REMOVED AND REPLACED ON |
| | A BUILDING THAT IS LOCATED IN THE WIND-BORNE DEBRIS |
| | REGION AS DEFINED IN THE FLORIDA BUILDING CODE, |
| | BUILDING AND THAT HAS AN INSURED VALUE OF $300,000 OR |
| | MORE OR, IF THE BUILDING IS UNINSURED OR FOR WHICH |
| | DOCUMENTATION OF INSURED VALUE IS NOT PRESENTED, HAS A |
| | JUST VALUATION FOR THE STRUCTURE FOR PURPOSES OF AD |
| | VALOREM TAXATION OF $300,000 OR MORE: |
| | (A)ROOF TO WALL CONNECTIONS SHALL BE IMPROVED AS |
| | REQUIRED BY SECTION 706.8.1. |
| | (B)MANDATED RETROFITS OF THE ROOF-TO-WALL CONNECTION |
| | SHALL NOT BE REQUIRED BEYOND A 15 PERCENT INCREASE IN |
| | THE COST OF REROOFING. |
| | EXCEPTION: SINGLE-FAMILY RESIDENTIAL STRUCTURES |
| | PERMITTED SUBJECT TO THE FLORIDA BUILDING CODE ARE NOT |
| | REQUIRED TO COMPLY WITH THIS SECTION. |
| | |
| | |
| | 2- CLEARLY MARK THE ADHESIVE PADDY SIZE ON ROOF TILE |
| | AND ON ADHESIVE PRODUCT APPROVAL SUBMITTED AS REQUIRED |
| | BY CITY POLICY FOR ROOFING PERMITS TO VERIFY COMPLIANCE |
| | WITH PROPOSED INSTALLATION. SEC. 107.2.1 CITY |
| | AMENDMENTS. |
| | |
| | 3- BORAL TILESEAL ROOFING UNDERLAYMENT NOA 17-0530.10 |
| | SUBMITTED EXPIRED ON 07/31/18. PROVIDE CURRENT NOA. |
| | FAC 61G20.3.001 |
| | |
| | |
| | |
| | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT |
| | JULIO GOMEZ |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | BUILDING DIVISION |
| | (561)805-6712 |
| | [email protected] |
| | |
| | |