Plan Review Notes
Plan Review Notes For Permit 18090353
Permit Number 18090353
Review Stop P
Sequence Number 1
Notes
Date Text
2018-10-30 07:54:32APPROVED
 PROVISO
 1. CONNECT LAVATORY TO VENT ABOVE THE WATER CLOSET
 CONNECTION. FBC PL 911.3
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 PHONE 561-805-6715
  
2018-10-04 09:15:39CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION
 FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION
 FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
 1ST REVIEW:
 PLUMBING COMMENTS: DENIED
  
 1. RE: PLAN SHEET A-1; PROVIDE PIPING MATERIALS TYPE &
 FIRE RATED ASSEMBLIES FOR NEW OR RELOCATED PIPING FLOOR
 PENETRATIONS. WPB FBC 107.2.1
 2. RE: PLAN SHEET A-1; IS EXISTING 2" SANITARY PART OF
 A WET VENTED SYSTEM. PLEASE CLARIFY AND PROVIDE RISER
 DIAGRAM TO SHOW HOW SHOWER DRAIN WILL BE VENTED. WPB
 FBC 107.2.1
 3. RE: PLAN SHEET A-1; SANITARY RISER FOR WALL MOUNTED
 WATER CLOSET. PLEASE SHOW ON THE RISER DIAGRAM THE
 LAVATORY FIXTURE DRAIN CONNECTION. WPB FBC 107.2.1
 4. RE: PLAN SHEET A-1; PROVIDE SHOWER FLOOR AND SEAT
 DETAIL PER WPB FBC 107.2.1 SHOWING COMPLIANCE WITH FBC
 PL 417.
 5. PROVIDE FOOTPRINT OF ROOM TO BE RENOVATED SHOWING
 ORIGINAL CONFIGURATION. WPB FBC 107.2.1
 6. PROVIDE THE FOLLOWING NOTES PER WPB FBC 107.2.1
 A. SHOWER CONTROL VALVE(S) SHALL BE PRESSURE BALANCED
 PB,THERMOSTATIC MIXING (TM) OR COMBINATION PB/TM VALVE
 TYPES WITH HIGH TEMPERATURE LIMITING STOP. FPC PL 424.3
 B. HAND HELD SHOWER REQUIRES AN ATMOSPHERIC VACUUM
 BREAKER AT SHOWER ARM OUTLET. FPC PL 424.4
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY
 REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED
 SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED "VOID".
  
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 PHONE 561-805-6715