Plan Review Notes
Plan Review Notes For Permit 18081528
Permit Number 18081528
Review Stop B
Sequence Number 3
Notes
Date Text
2019-07-05 11:00:07REVIEW COMMENTS
  
 3RD REVIEW: FBC SIXTH EDITION (2017)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
 WPB PERMIT: 18081528
 ADD: 1515 S. FLAGLER DRIVE
 CONT:
 TEL:
 EMAIL:
  
 1) ART IN PUBLIC PLACES - WILL COMPLY.
  
 2) COMPLIED.
  
 3) COMPLIED.
  
 4) COMPLIED.
  
 5) COMPLIED.
  
 6) COMPLIED.
  
 7) COMPLIED.
  
 8) COMPLIED.
  
 9) COMPLIED.
  
 10) COMPLIED.
  
 11) COMPLIED.
  
 12) COMPLIED.
  
 13) COMPLIED.
  
 14) COMPLIED..
  
 15) COMPLIED.
  
 16) COMPLIED.
  
 17) COMPLIED.
  
 18) COMPLIED.
  
 19) COMPLIED.
  
 20) COMPLIED.
  
 21) COMPLIED.
  
 22) COMPLIED.
  
 23) COMPLIED.
  
 24) COMPLIED.
  
 25) COMPLIED.
  
 26) COMPLIED.
  
 27) COMPLIED.
  
 28) COMPLIED.
  
 29) COMPLIED.
  
 30) COMPLIED.
  
 31) COMPLIED.
  
 32) COMPLIED.
  
 33) COMPLIED.
  
 34) COMPLIED.
  
 35) COMPLIED.
  
 36) COMPLIED.
  
 37) COMPLIED.
  
 38) COMPLIED.
  
 39)COMPLIED.
  
 40) NOT COMPLIED. SOME OF THE ITEMS THAT ARE LISTED AS
 DEFERRED ON SHEET G-7 ARE REQUIRED TO HAVE SEPARATE
 PERMITS, APPLICATIONS AND REVIEWS. SEPARATE PERMITS ARE
 REQUIRED FOR GENERATORS, IRRIGATION, LANDSCAPE, POOLS
 AND FENCES. THESE ITEMS REQUIRING SEPARATE PERMITS
 SHOULD NOT BE LISTED AS DEFERRED (NO FEE) SUBMITTALS.
 PROVIDE A LIST OF THE ITEMS THAT WILL BE DEFERRED ON
 THE PLANS. FBC 107.3.4.1 DEFERRED SUBMITTALS. FOR THE
 PURPOSES OF THIS SECTION, DEFERRED SUBMITTALS ARE
 DEFINED AS THOSE PORTIONS OF THE DESIGN THAT ARE NOT
 SUBMITTED AT THE TIME OF THE APPLICATION AND THAT ARE
 TO BE SUBMITTED TO THE BUILDING OFFICIAL WITHIN A
 SPECIFIED PERIOD. DEFERRAL OF ANY SUBMITTAL ITEMS SHALL
 HAVE THE PRIOR APPROVAL OF THE BUILDING OFFICIAL. THE
 REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE
 SHALL LIST THE DEFERRED SUBMITTALS ON THE CONSTRUCTION
 DOCUMENTS FOR REVIEW BY THE BUILDING OFFICIAL.
  
 41) DEFERRED. W. P. B. 107.3.4.1 PRODUCT APPROVALS.
 THOSE PRODUCTS WHICH ARE REGULATED BY THE DCA RULE
 9N-03 SHALL BE REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR
 JURISDICTIONAL APPROVAL. FL 61G1-23.015 (2) THE
 ARCHITECT IS RESPONSIBLE FOR SUPERVISING AND REVIEWING
 ALL PROJECT DATA, REPORTS, SHOP DRAWINGS ETC.
 DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE
 SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN
 RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD
 THEM TO THE BUILDING OFFICIAL WITH A NOTATION
 INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE
 BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO
 THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL
 ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED
 SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING
 OFFICIAL.
  
 42) PARTIAL COMPLIANCE. THIS NOTE IS INCORRECTLY WORDED
 AND NEEDS TO BE REVISED. FBC 1207.2 ADDRESSES
 AIR-BOURNE SOUND THAT WHEN TESTED IN ACCORDANCE WITH
 ASTM E90 IS REQUIRED TO HAVE A SOUND TRANSMISSION CLASS
 (STC) OF NOT LESS THAN 50 OR NOT LESS THAN 45 IF TESTED
 IN THE FIELD. FBC 1207.3 ADDRESSES STRUCTURE-BOURNE
 SOUND THAT WHEN TESTED IN ACCORDANCE WITH ASTM E492 IS
 REQUIRED TO HAVE AN IMPACT INSULATION CLASS (IIC)
 RATING OF NOT LESS THAN 50 OR NOT LESS THAN 45 WHEN
 TESTED IN THE FIELD. REVISE THE NOTE ON THE PLAN TO
 INCLUDE ASTM E 492. SHOW COMPLIANCE WITH FBC 1207.2 FOR
 AIR-BORNE SOUND TRANSMISSION AND FBC 1207.3 FOR
 STRUCTURE BORNE SOUND INSULATION.
  
 43) COMPLIED.
  
 44) COMPLIED.
  
  