| 2018-12-06 11:22:10 | 1ST REVIEW: |
| | 2017 FLORIDA BUILDING CODE 6TH EDITION |
| | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION |
| | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH |
| | EDITION |
| | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION |
| | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION |
| | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH |
| | EDITION |
| | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH |
| | EDITION |
| | |
| | PLUMBING COMMENTS: |
| | 1. PLEASE STATE ON THE PLAN WHICH FHA DOCUMENT YOU ARE |
| | USING TO DESIGN THIS PROJECT. PER WPB AMEND TO FBC |
| | 107.2.1 |
| | 2. ALL COMMON AREA BATHROOMS SHALL COMPLY WITH ANSI |
| | A117.1-1986 PLEASE SHOW COMPLIANCE WITH THE FOLLOWING. |
| | A) THE SIDE WALL GRAB BAR AT THE TOILET SHALL BE 42 |
| | INCHES LONG MINIMUM, LOCATED 12 INCHES MAXIMUM FROM THE |
| | REAR WALL AND EXTENDING 54 INCHES MINIMUM FROM THE REAR |
| | WALL. PER ANSI A117.1-1986 4.17.6 |
| | A) THE REAR WALL GRAB BAR SHALL BE 36 INCHES LONG |
| | MINIMUM AND EXTEND FROM THE CENTERLINE OF THE WATER |
| | CLOSET 12 INCHES MINIMUM ON ONE SIDE AND 24 INCHES |
| | MINIMUM ON THE OTHER SIDE. PER ANSI A117.1-1986 4.17.6 |
| | B) LABEL ALL CLEAR FLOOR SPACE WITH DIMENSIONS PER ANSI |
| | A117.1-1986 4.17.3 AND4.19.2.2 |
| | C) SHOWER STALLS SHALL COMPLY WITH ANSI A117.1-1986 |
| | 4.21 |
| | 3. PLEASE LABEL ALL COMMON AREA BATHROOMS MEN'S OR |
| | WOMEN SEPARATE FACILITIES REQUIRED. PER FBC PL 403.2 |
| | 4. PROVIDE PLUMBING FIXTURE COUNT BREAKDOWN PER AREA. |
| | WPB AMEND TO FBC 107.2.1 |
| | 5. SEPARATE FACILITIES REQUIRED FOR ROOMS 211 AND 213 |
| | AND SURROUNDING AREA. PER FBC PL 403.2 |
| | 6. THE LINE FOR THE INTERIOR WALLS AND FIXTURES ARE |
| | EXTREMELY LIGHT SOME PLUMBING FIXTURES ARE MISSING ON |
| | THE FLOOR PLANS PLEASE DARKEN LINES AND INCLUDE FIXTURE |
| | ON ALL FLOOR PLAN SHEETS. PER WPB AMEND TO FBC |
| | 7. PLEASE PROVIDE A SCHEDULE OF THE FHA BATHROOMS WITH |
| | UNIT AND SPEC TYPE MARKED. PER WPB AMEND TO FBC 107.2.1 |
| | 8. SHOW THE CLEAR FLOOR SPACE FOR ALL THE FHA |
| | LAVATORY?S. PER FHA REQUIREMENT #7 |
| | |
| | 9. SHT A-771 AND A-772 DETAILS #12 + 17 THE CLEAR FLOOR |
| | SPACE FOR THE LAVATORY SEEMS TO BE ENCROACHED BY THE |
| | TOILET. PLEASE CLARIFY. PER FHA REQUIREMENT #7 |
| | 10. IN THE SPEC B BATHROOMS THE CLEAR FLOOR SPACE FOR |
| | THE SHOWERS SHALL LINE UP WITH THE CONTROL WALLS. PER |
| | FHA REQUIREMENT #7 |
| | 11. WHERE THE DOOR SWING IS INTO THE BATHROOM A 30"X48" |
| | CLEAR FLOOR SPACE OUTSIDE OF THE DOOR SWING IS |
| | REQUIRED. . PER FHA REQUIREMENT #7 |
| | 12. PLEASE PROVIDE ELEVATION OF LAVATORY IN GUEST SUITE |
| | BATHROOMS. . PER FHA REQUIREMENT #7 |
| | 13. SHT A-790/ A-791/ A-792 THE DRAWING ARE EXTREMELY |
| | LIGHT PLEASE DARKEN. PER WPB AMEND TO FBC 107.2.1 |
| | 14. THE KITCHEN SINK IN THE PRIVATE DINING ROOM AND |
| | CATERING AREA SHALL BE REQUIRED TO DISCHARGE THROUGH A |
| | GREASE INTERCEPTOR. PER FBC PL 1003.3.1 |
| | 15. PROVIDE MANUFACTURE SPECIFICATION FOR RUBBERIZED |
| | SHOWER PAN LINER TO COMPLY WITH FBC PL 417.5.2- |
| | 417.5.2.6 |
| | 16. PROVIDE DETAIL FOR EMERGENCY SCUPPER WITH |
| | DIMENSIONS. PER WPB AMEND TO FBC 107.2.1 |
| | 17. PLEASE PROVIDE ISOMETRIC DRAWINGS FOR WATER |
| | SANITARY AND STORM DRAINS. THE RISERS SHOWN ON THE PLAN |
| | DO NOT PROVIDE SUFFICIENT DETAIL TO DETERMINE CODE |
| | COMPLIANCE YOU CAN PROVIDE ENLARGE DETAIL ISOMETRICS |
| | FOR INDIVIDUAL BATHROOM GROUPS AND COMMON AREAS. PER |
| | WPB AMEND TO FBC 107.2.1 |
| | 18. PLEASE SHOW THE TAGS FOR THE SS AND WATER STACKS ON |
| | THE ENLARGED FLOOR PLANS. PER WPB AMEND TO FBC 107.2.1 |
| | 19. PROVIDE DETAIL WITH DIMENSIONS FOR GRAB BAR BACKING |
| | IN ALL BATHROOMS. FHA REQUIREMENT #6 |
| | |
| | |
| | |
| | |
| | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT |
| | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID |
| | THE PREVIOUSLY REVIEWED SHEETS. |
| | |
| | GEORGE JOHNSON |
| | PLUMBING PLANS EXAMINER |
| | CITY OF WEST PALM BEACH |
| | 561-805-6711 |
| | [email protected] |
| | |