| Plan Review Notes For Permit 18081507 |
| Permit Number |
18081507 |
|
| Review Stop |
FIRE |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2018-11-20 13:08:21 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | | INSPECTION. | | | | | | | | | 1) SHEET LS 1 - AN EXIT SIGN IS INDICATED WITHIN A | | | CLOUD IN THE ACCOUNTING ROMM LEADING INTO THE STORAGE | | | AREA. THIS EXIT IS NOT REQUIRED, ADDITIONALLY, AN EXIT | | | FROM AN AREA OF LOWER HAZARD CAN NTO EXIT INTO AN AREA | | | OF HIGHER HAZARD. | | | | | | PLEAE OMIT THIS EXIT SIGN. | | | | | | 7.5.1.6 EXIT ACCESS FROM ROOMS OR SPACES SHALL BE | | | PERMITTED TO BE THROUGH ADJOINING OR INTERVENING ROOMS | | | OR AREAS, PROVIDED THAT SUCH ROOMS OR AREAS ARE | | | ACCESSORY TO THE AREA SERVED. FOYERS, LOBBIES, AND | | | RECEPTION ROOMS CONSTRUCTED AS REQUIRED FOR CORRIDORS | | | SHALL NOT BE CONSTRUED AS INTERVENING ROOMS. EXIT | | | ACCESS SHALL BE ARRANGED SO THAT IT IS NOT NECESSARY TO | | | PASS THROUGH ANY AREA IDENTIFIED UNDER PROTECTION FROM | | | HAZARDS IN CHAPTERS 11 THROUGH 43. | | | | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|