| 2018-10-16 09:57:38 | CODES IN EFFECT: |
| | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION |
| | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 |
| | 6TH ED, CHAPTER 1. |
| | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 |
| | 6TH EDITION |
| | FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION |
| | FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION |
| | FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH |
| | EDITION |
| | FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION |
| | FAC= FLORIDA ADMINISTRATIVE CODE |
| | FS = FLORIDA STATUTES |
| | |
| | |
| | 1ST REVIEW: DENIED |
| | |
| | PLUMBING COMMENTS: |
| | 1. THERE ARE NO PLUMBING PLANS. PLUMBING PLANS ARTE NOT |
| | REQUIRED BASED ON THE SCOPE OF WORK INDICATED ON THE |
| | EXISTING PLANS. THE PLUMBING WORK IS NOTED ON PLAN |
| | SHEETS A1-101, ID-101 AND CONSISTS OF REMOVAL OF |
| | EXISTING CORRIDOR TOILET ROOM FIXTURES AND TEMPORARILY |
| | CAPPING EXISTING PLUMBING SERVICE CONNECTIONS TO ALLOW |
| | NEW WALL AND FLOOR FINISHES TO BE PUT IN PLACE. THE |
| | ORIGINAL WATER CLOSETS AND URINALS WILL BE REINSTALLED. |
| | NEW LAVATORIES WILL BE INSTALLED IN NEW VANITIES (SEE |
| | PLAN SHEET 1A-700; BATHROOM EQUIPMENT SPECS). ALL WILL |
| | BE RECONNECTED TO EXISTING PLUMBING SERVICE |
| | CONNECTIONS. |
| | A) RE: PLAN SHEET G002 ; 22000 PLUMBING, SUMMARY NOTE |
| | 1.REPLACE THE WORDS "BUILDING PLUMBING DRAWINGS" WITH |
| | THE WORDS "PLAN SHEET A1-700". |
| | B) RE: PLAN SHEET ID-101; ADD DEMOLITION KEYED NOTE 12 |
| | ?CAP EXISTING PLUMBING SERVICE CONNECTIONS? AND NOTE |
| | SAME ON FLOOR PLAN WHEREVER NOTES 5 AND 11 ARE |
| | DESIGNATED PER WPB FBC 107.2.1 |
| | 2. BASED ON CONVERSATIONS WITH THE APPLICANT, THE SCOPE |
| | OF WORK IS LIMITED TO THE CORRIDOR TOILET ROOMS ON THE |
| | FIRST AND SECOND FLOOR ONLY, AND IS REINFORCED BY PLAN |
| | SHEET 1A-101: DETAIL 1; A1-1A-700 WITH NOTE STATING |
| | "LIMITS OF ALTERATION LEVEL 1" . THE FIRST FLOOR LOBBY |
| | AREA NOTED ON PLAN SHEET A1-101: DETAIL 1; A1-702 AND |
| | PLAN SHEET A1-702 IS NOT INCLUDED IN THE SCOPE OF WORK. |
| | A) PLEASE REMOVE FROM PERMIT PLANS SHEETS AND DETAILS |
| | THAT INDICATE WORK IN THE FIRST FLOOR LOBBY INCLUDING |
| | PLAN SHEET A1-702, 1A-801, AND DETAILS ON PLAN SHEET |
| | A1-851 THAT DO NOT SPECIFICALLY ADDRESS THE CORRIDOR |
| | TOILET ROOMS, OR |
| | I. CLARIFY ON PLAN SHEET A1-101 THAT THIS AREA IS |
| | INCLUDED IN THE "LIMITS OF ALTERATION LEVEL 1", ADD TO |
| | PLAN SHEET G002 ; 22000 PLUMBING, SUMMARY NOTE 1. ADD |
| | THE WORDS "AND PLAN SHEET A1-702" AFTER THE WORDS "PLAN |
| | SHEET A1-700" AND ADJUST VALUE OF WORK ON PERMIT |
| | APPLICATION TO REFLECT SUCH PER WPB FBC 107.2.1 |
| | 3. TEMPERED WATER SHALL BE DELIVERED FROM LAVATORIES |
| | LOCATED IN PUBLIC TOILET ROOMS THROUGH AN APPROVED |
| | WATER-TEMPERATURE LIMITING DEVICE THAT CONFORMS TO ASSE |
| | 1070 OR CSA B125.3 PER FBC PL 416.5. PLEASE NOTE ON |
| | PLAN SHEET 1A-700; BATHROOM EQUIPMENT SPECS. |
| | |
| | |
| | JERALD SMITH |
| | PLUMBING PLANS EXAMINER |
| | CITY OF WEST PALM BEACH |
| | EMAIL [email protected] |
| | PHONE 561-805-6715 |
| | |