| Date |
Text |
| 2019-04-18 13:35:59 | CODES IN EFFECT: |
| | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION |
| | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 |
| | 6TH ED, CHAPTER 1. |
| | FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION |
| | WPB CCC = WEST PALM BEACH CROSS CONNECTION CONTROL |
| | MANUAL |
| | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 |
| | 6TH EDITION |
| | FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION |
| | FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION |
| | FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH |
| | EDITION |
| | FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION |
| | FAC= FLORIDA ADMINISTRATIVE CODE |
| | FS = FLORIDA STATUTES |
| | |
| | 2ND REVIEW |
| | PLUMBING COMMENTS: DENIED |
| | SECOND REQUEST FOR ALL COMMENTS |
| | 1. PROVIDE SANITARY RISER DIAGRAM IDENTIFYING FUTURE |
| | FIXTURES PER FBC RES P3005.4 AND WPB FPC 107.3.5.3(12). |
| | INDICATE BELOW FLOOR FIXTURE TRAPS WHERE REQUIRED AND |
| | VENTING OF ALL FIXTURE DRAINS PER FBC RES P3104.6. |
| | VENTING TO BE IN ACCORDANCE WITH FBC RES SECTION P3105. |
| | A. RISER DIAGRAM AND FLOOR PLAN TO MATCH PER WPB FBC |
| | 107.2.1 |
| | 2. PROVIDE ONE (1) VENT EXTENDED TO OUTDOORS AS PART OF |
| | INITIAL INSTALLTION PER P3102.1. |
| | 3. PROVIDE ELEVATION TYPE DETAIL(MAY BE PROVIDED ON |
| | A-400 OR OTHER A SHEET WITH A NOTE ON PLUMBING PLAN |
| | REFERRING TO DETAIL ON A SHEET)SHOWING HOW PIPING WILL |
| | BE SECURED AND PROTECTED IN SLAB. PIPING SUPPORT SHALL |
| | BE COMPLIANT WITH THE PROVISIONS OF FBC RES SECTION |
| | P2605 . PROVIDE ELEVATIONS OF PIPING ON FLOOR PLAN IN |
| | RELATIONSHIP TO EXISTING SLAB FINISH FLOOR AND NEW SLAB |
| | FINISH FLOOR AT BUILDING EXIT, EACH BRANCH CONNECTION |
| | TO BUILDING DRAIN, INLET END OF EACH BRANCH AND HIGH |
| | END OF BUILDING DRAIN INDICATING THAT THE SPACE ALLOWED |
| | IN ADDED 5 1/2" THICK CONCRETE SLAB TOPPING ALLOWS FOR |
| | ADEQUATE SLOPE OF DRAINAGE PIPING PER FBC RES P3005.3. |
| | SEE WPB FBC 107.2.1.2. |
| | 4. DETAILS SHOWING PIPING WORK IN SLAB MUST BE REVIEWED |
| | BY BUILDING/STRUCTURAL EXAMINER AS WELL FOR COMPLIANCE |
| | PER WPB FBC 107.2.1.2 AND SHALL BE INCLUDED ON A-400 OR |
| | OTHER A SHEET. |
| | |
| | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN |
| | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES |
| | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY |
| | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED |
| | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED "VOID". |
| | |
| | |
| | |
| | JERALD SMITH |
| | PLUMBING PLANS EXAMINER |
| | CITY OF WEST PALM BEACH |
| | EMAIL [email protected] |
| | PHONE 561-805-6715 |