Plan Review Notes
Plan Review Notes For Permit 18081031
Permit Number 18081031
Review Stop B
Sequence Number 1
Notes
Date Text
2018-09-27 11:22:34****CORRECTIONS****
 W.P.B. PERMIT: 18081031
 REVIEWED: SEPTEMBER 27, 2018
  
 DYLAN BATTLES
 BUILDING PLANS EXAMINER I
 [email protected]
 561-805-6718
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC AMENDED = FLORIDA BUILDING CODE,6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC ENERGY = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 1. [FBC 107.2.5]PROVIDE SURVEY OF PROPERTY SHOWING
 EASEMENTS.
  
 2. [FBC AMENDED 109]PROVIDE COPY OF PROPOSAL WITH
 CONTRACTOR TO SHOW WORK VALUE EQUAL TO THE AMOUNT SHOWN
 ON PERMIT APPLICATION. VALUE SHOULD INCLUDE ALL DEMO,
 INTERIOR WORK, TRUSSES AND ROOFING.
 VALUE WILL NOT INCLUDE DRIVEWAY AND SIDEWALK. THE FEES
 FOR THESE WILL BE ASSESSED THROUGH ENGINEERING DRIVEWAY
 PERMIT.
  
 3. [FBC 107.3.5.3]PROVIDE PROJECT DESIGN DATA:
 -LEVEL OF ALTERATION
 -EXISTING SQ. FOOTAGE UNDER AIR AND NOT UNDER AIR.
 -PROPOSED SQ. FOOTAGE UNDER AIR AND NOT UNDER AIR.
 -PERCENTAGE OF AREA AFFECTED BY WORK.
 -LABEL EXISTING SPACES WHERE WORK IS OCCURING
 -LABEL WHAT PROPOSED SPACES ARE BECOMING.
  
 4. FBC R301.2.1]PROVIDE WIND DESIGN CRITERIA AND DESIGN
 PRESSURES FOR WINDOW AND DOOR OPENINGS.
  
 5. [FBC R3-1.2(6)]PROVIDE WIND DIAGRAM THAT MATCHES THE
 ROOF CONDITION OF THIS HOUSE.
  
 6. [FBC 107.2.5]IS THE EXISTING SPACE UNDER AIR AND
 WILL THE NEW SPACE BE AIR CONDITIONED?
 PROVIDE HOW THE ENERGY CODE IS BEING MET AND PROVIDE
 DETAILS ABOUT INSULATION IN THE CEILING AND WALLS.
 ARE THERE ANY WALL/CEILING FINISHES? DRYWALL OR STUCCO?
  
 7. [FBC 107.2.5]IS THERE ANY ELECTRICAL OR MECHANICAL
 WORK FOR THIS PROJECT?
  
 8. [FBC R806]SUPPLY VENTING CALCULATIONS FOR THE ATTIC
 AND HOW THE AREA OF VENTING WILL BE ACHIEVED.
 IF OFF RIDGE VENTS BEING USED SUPPLY PRODUCT APPROVAL,
 OR DEFER WITH ROOF SUBMITTAL.
  
 9. [FBC R807]BUILDINGS WITH COMBUSTIBLE CEILING OR ROOF
 CONSTRUCTION SHALL HAVE AN ATTIC ACCESS OPENING TO
 ATTIC AREAS THAT HAVE A VERTICAL HEIGHT OF 30 INCHES
 (762 MM) OR GREATER OVER AN AREA OF NOT LESS THAN 30
 SQUARE FEET (2.8 M2).
  
 10. [FBC R903.2.2]CRICKETS AND SADDLES.
 A CRICKET OR SADDLE SHALL BE INSTALLED ON THE RIDGE
 SIDE OF ANY CHIMNEY OR PENETRATION MORE THAN 30 INCHES
 (762 MM) WIDE AS MEASURED PERPENDICULAR TO THE SLOPE.
 CRICKET OR SADDLE COVERINGS SHALL BE SHEET METAL OR OF
 THE SAME MATERIAL AS THE ROOF COVERING.
 WHERE THE NEW TIE BEAM EXTENDS UP PAST THE NEW TRUSSES,
 BEST SHOWN IN SHEET A-300 PROPOSED BUILDING SECTION,
 HOW WILL WATER SHED IN THE VALLEY WITHOUT ANY PITCH?
  
 11. [FBC R301.4] [FBC R301.5]PROVIDE LIVE LOAD AND DEAD
 LOAD FOR NEW ROOFING.
  
 12. [FBC AMENDED 107.3.4.1]PROVIDE PRODUCT APPROVALS
 FOR ROOFING, OR INDICATE THAT YOU WOULD LIKE THEM
 DEFERED.
  
 13. [FBC AMENDED 107.3.4.1]SUBMIT TRUSS SHOP DRAWINGS
 TO THE BUILDING INSPECTOR PRIOR TO INSTALLATION
  
 NOTE:
 -PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW
 EACH COMMENT IS BEING ADDRESSED.
 -ADDITIONAL COMMENTS MAY BE FORTHCOMING PENDING REVIEW
 OF MATERIALS REQUESTED.
 -WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS
 OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS)
 SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT
 DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER
 SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID"
 OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS
 APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE
 NEED "VOID", RENDERING THEM NOT USABLE.
  