| 2018-08-31 09:10:17 | ****CORRECTIONS**** |
| | W.P.B. PERMIT: 18080967 |
| | REVIEWED: AUGUST 31, 2018 |
| | |
| | DYLAN BATTLES |
| | BUILDING PLANS EXAMINER I |
| | [email protected] |
| | 561-805-6718 |
| | |
| | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) |
| | FBC EB = FBC EXISTING BUILDING |
| | FBC R = FBC RESIDENTIAL |
| | |
| | 1. [FBC R802.11.1.2]RAFTER UPLIFT RESISTANCE. |
| | INDIVIDUAL RAFTERS SHALL BE ATTACHED TO SUPPORTING WALL |
| | ASSEMBLIES BY CONNECTIONS CAPABLE OF RESISTING UPLIFT |
| | FORCES AS DETERMINED BY TABLE R802.11 OR AS DETERMINED |
| | BY ACCEPTED ENGINEERING PRACTICE. CONNECTIONS FOR BEAMS |
| | USED IN A ROOF SYSTEM SHALL BE DESIGNED IN ACCORDANCE |
| | WITH ACCEPTED ENGINEERING PRACTICE. |
| | A. PROVIDE ROOF LOADS FOR GRAVITY AND UPLIFT. |
| | B. SHOW THE ROOF PITCH. |
| | C. WHAT CONNECTOR IS USED FOR 3X6 RAFTERS TO LEDGER? |
| | |
| | 2. [FBC R803.2.3.1]SHEATHING FASTENING. |
| | SHEATHING NAILS TO BE RING SHANK RSRS01(2 3/8 X 0.113) |
| | |
| | NOTE: |
| | -PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW |
| | EACH COMMENT IS BEING ADDRESSED. |
| | -ADDITIONAL COMMENTS MAY BE FORTHCOMING PENDING REVIEW |
| | OF MATERIALS REQUESTED. |
| | -WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS |
| | OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS) |
| | SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT |
| | DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER |
| | SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID" |
| | OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS |
| | APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE |
| | NEED "VOID", RENDERING THEM NOT USABLE. |
| | |