| Plan Review Notes For Permit 18080440 |
| Permit Number |
18080440 |
|
| Review Stop |
P |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2018-08-22 10:22:41 | 1) SUBMIT A FLOOR PLAN FOR THE BATHROOM WHERE THE WORK | | | IS BEING PERFORMED. THIS BUILDING WAS BUILT IN | | | COMPLIANCE WITH THE FAIR HOUSING ACT AND FULL | | | COMPLIANCE MUST BE MAINTAINED. | | | 2) THE HEIGHT OF THE NEW LAVATORY CABINET BEING | | | INSTALLED CANNOT EXCEED 34 INCHES FROM THE FINISH FLOOR | | | TO THE TOP OF THE COUNTER PER THE FAIR HOUSING ACT. | | | 3) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE WATER | | | HEATER TO BE REPLACED. WPB AMEND. TO FBC SEC. 107.2.1. | | | 4) SUBMIT MANUFACTURER'S SPECIFICATIONS/INSTALLATION | | | INSTRUCTIONS FOR THE NEW TUB TO BE INSTALLED. WPB | | | AMEND. TO FBC SEC. 107.2.1. | | | 5) THE BATHTUB VALVE SHALL BE EQUIPPED WITH A WATER | | | TEMPERATURE LIMITING DEVICE THAT LIMITS THE TEMPERATURE | | | OF THE WATER TO 120 DEGREES AND THAT CONFORMS TO ASSE | | | 1070 PER THE 2017 FBC-PLUMBING SEC.424.5. | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | |
|