| Plan Review Notes For Permit 18080282 |
| Permit Number |
18080282 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2018-09-02 15:43:46 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. FBC B 2508.2, PLAN PROPOSES "GP DRYWALL ON NEW AND | | | PREPARED AREAS". GYPSUM WALLBOARD SHALL NOT BE USED IN | | | AREAS OF HIGH HUMIDITY. IT IS NOT CLEAR WHERE "NEW AND | | | PREPARED" AREAS ARE; REVISE PLAN TO CLARIFY PROPOSED | | | INSTALLATION AND COMPLIANCE. | | | | | | 2. FBC B 2509, DRYWALL CANNOT BE USED IN SHOWERS; | | | REVISE PLAN TO CLARIFY BACKERBOARD PROPOSED. | | | | | | |
|