Plan Review Notes
Plan Review Notes For Permit 18080195
Permit Number 18080195
Review Stop B
Sequence Number 2
Notes
Date Text
2018-09-12 10:15:39APPROVED PROVISIONALLY. DO YOU KNOW WHICH WINDOW YOU
 ARE USING FROM THE FLORIDA PRODUCT APPROVAL NUMBER
 243-R20 ? I PRESUMED IT IS 243.5. YOU DID NOT PROVIDE
 THE CERTIFICATE AGENCY CERTIFICATE OR INSTALLATION
 INSTRUCTION. I PRINTED IT FOR YOU WHICH TURNED OUT TO
 BE MIAMI DADE NOA 17-0614.11. I ATTACHED ONLY THE NOA
 TO THE PLAN AS THE FLORIDA PRODUCT APPROVAL SHEET JUST
 CONFUSES THE ISSUE. YOUR ENGINEER OF RECORD, ANDRE H.
 THOMAS IS SUPPOSED TO PROVIDE EVIDENCE THAT HE REVIEWED
 THE USE OF THIS PRODUCT FOR CONSISTENCY WITH THE DESIGN
 OTHER ISSUES THAT WERE NOT ADDRESSED IN THE RESPONSE
 SHOULD ALSO BE PROVIDED BY THE ENGINEER AS HE IS
 RESPONSIBLE FOR THE DESIGN. THOSE ITEMS ARE AS FOLLOWS:
  
 1. [FBC EB501]PROVIDE DESIGN DATA: OCCUPANCY=R-3, LEVEL
 OF ALTERATION AND TYPE OF CONSTRUCTION.
  
 2. [FBC 107.2.5]PROVIDE FURTHER DETAIL SHEET A-1 BLOCK
 IN-FILL. WHAT IS THE EXTERIOR FINISH, INSULATION AND
 INTERIOR FINISH.
  
 3. [FBC ENERGY R503.1.1.1]WHERE SOME OR ALL OF AN
 EXISTING FENESTRATION UNIT IS REPLACED WITH A NEW
 FENESTRATION PRODUCT, INCLUDING SASH AND GLAZING, THE
 REPLACEMENT FENESTRATION UNIT SHALL MEET THE APPLICABLE
 REQUIREMENTS FOR U-FACTOR AND SHGC AS PROVIDED IN TABLE
 R402.1.2.
 NEW FENESTRATION SHOULD HAVE MAXIMUM SOLAR HEAT GAIN
 CO-EFFICIENT (SHGC) OF 0.25 IN CLIMATE ZONE 1.
  
 THE ENGINEER MAY PROVIDE A LETTER ADDRESSING THESE
 ISSUES FOR MY REVIEW OR IT MAY BE GIVEN TO THE BUILDING
 INSPECTOR AT THE FRAMING INSPECTION.
  
 STEVEN KENNEDY, CBO
 ASSISTANT BUILDING OFFICIAL
 (561) 805-6710
 [email protected]
  
  