| 2018-08-10 07:43:19 | 1) PLEASE PROVIDE 3000 PSI CONCRETE PER CITY GENERAL | | | CONSTRUCTION STANDARD DETAIL GC-6. | | | 2) PLEASE CLARIFY IF DRIVEWAY IS BEING WIDENED. WORK | | | DESCRIPTION ON APPLICATION IS SHOWN AS "SIDEWALK". | | | 3) SUBMITTED DRAWING APPEARS TO SHOW A PROPOSED | | | EXPANDED DRIVEWAY (25 FEET? NOT CALLED OUT) WITH A | | | FINAL PROPOSED WIDTH OF 29 FEET INCLUDING FLARES. CITY | | | GENERAL CONSTRUCTION STANDARD DETAIL GC-6 ALLOWS FOR 20 | | | FOOT MAX. DRIVEWAY WIDTH WITH ADDITIONAL 3 FT. FLARE ON | | | EACH SIDE. | | | 4) CALL 811 FOR UTILITY LOCATES PROIR TO CONSTRUCTION | | | 48 HOURS BEFORE DIGGING. | | | 5) STREETVIEW SHOWS A TREE TO THE EAST OF THE EXISTING | | | DRIVEWAY THAT MAY BE IMPACTED BY THE PROPOSED DRIVEWAY | | | WIDENING. PLEASE ADVISE. | | | | | | PLEASE RESPOND TO COMMENTS IN WRITING. | | | | | | RICK ROSSANO | | | PROJECT COORDINATOR | | | WPB ENGINEERING SERVICES | | | 401 CLEMATIS STREET, 4TH FLOOR | | | WEST PALM BEACH, FL 33401 | | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | | MAIN PHONE: (561) 822-1200 | | | DIRECT: (561) 494-1098 | | | CELL: (561) 246-9525 | | | FAX: (561) 494-1116 | | | EMAIL: [email protected] | | | WWW.WPB.ORG/ENGINEERING | | | | | | |
|