Plan Review Notes
Plan Review Notes For Permit 18071393
Permit Number 18071393
Review Stop P
Sequence Number 2
Notes
Date Text
2018-08-29 10:38:08NONE OF THE PREVIOUS PLUMBING REVIEW COMMENTS HAVE BEEN
 ADDRESSED.
 1) THIS STRUCTURE WAS BUILT IN 2001 AND THEREFORE WAS
 DESIGNED UNDER THE FAIR HOUSING ACT AND THE FAIR
 HOUSING ACT DESIGN MANUAL AS NOTED ON THE ORIGINAL
 PLANS ON FILE IN CITY RECORDS. THIS UNIT WAS DESIGNED
 AS A SPECIFICATION "A" TYPE BATHROOM.
 THE FAIR HOUSING ACT DESIGN MANUAL REQUIRES A 30 INCH
 WIDE BY 48 INCH DEEP CLEAR FLOOR SPACE BE PROVIDED AT
 SHOWER STALLS, PARALLEL TO THE FIXTURE AND FLUSH WITH
 THE CONTROL WALL. NO OTHER FIXTURE MAY OVERLAP THE
 CLEAR FLOOR SPACE AT SHOWERS EXCEPT AS PROVIDED IN THE
 FAIR HOUSING ACT DESIGN MANUAL. THE EXISTING DESIGN
 DOES NOT MEET ANY OF THE EXCEPTIONS. THE FLOOR PLAN
 SHOWS A WATER CLOSET NEXT TO WHERE THE PROPOSED SHOWER
 WOULD BE AND THEREFORE WOULD CREATE A VIOLATION OF THE
 FAIR HOUSING ACT. THE SHOWER CANNOT BE INSTALLED IN
 LIEU OF THE BATHTUB.
 2) INDICATE ON THE PLAN IF THE KITCHEN SINK WILL BE
 REPLACED.
  
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 PLUMBING PLAN REVIEW
 561-805-6692
 [email protected]
  