| Plan Review Notes For Permit 18071393 |
| Permit Number |
18071393 |
|
| Review Stop |
P |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2018-08-06 06:17:00 | 1) THIS STRUCTURE WAS BUILT IN 2001 AND THEREFORE WAS | | | DESIGNED UNDER THE FAIR HOUSING ACT AND THE FAIR | | | HOUSING ACT DESIGN MANUAL AS NOTED ON THE ORIGINAL | | | PLANS ON FILE IN CITY RECORDS. THIS UNIT WAS DESIGNED | | | AS A SPECIFICATION "A" TYPE BATHROOM. | | | THE FAIR HOUSING ACT DESIGN MANUAL REQUIRES A 30 INCH | | | WIDE BY 48 INCH DEEP CLEAR FLOOR SPACE BE PROVIDED AT | | | SHOWER STALLS, PARALLEL TO THE FIXTURE AND FLUSH WITH | | | THE CONTROL WALL. NO OTHER FIXTURE MAY OVERLAP THE | | | CLEAR FLOOR SPACE AT SHOWERS EXCEPT AS PROVIDED IN THE | | | FAIR HOUSING ACT DESIGN MANUAL. THE EXISTING DESIGN | | | DOES NOT MEET ANY OF THE EXCEPTIONS. THE FLOOR PLAN | | | SHOWS A WATER CLOSET NEXT TO WHERE THE PROPOSED SHOWER | | | WOULD BE AND THEREFORE WOULD CREATE A VIOLATION OF THE | | | FAIR HOUSING ACT. THE SHOWER CANNOT BE INSTALLED IN | | | LIEU OF THE BATHTUB. | | | 2) INDICATE ON THE PLAN IF THE KITCHEN SINK WILL NE | | | REPLACED. | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | |
|