| Plan Review Notes For Permit 18070617 |
| Permit Number |
18070617 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2018-07-18 12:36:26 | RESIDENTIAL (R3) PARTIAL RE-ROOF BUILDING REVIEW | | | COMMENTS | | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | | | | | 1- FLINTLASTIC SELF-ADHERING ROOFING SYSTEM NOA | | | 15-0622.21 IS NOT AN UNDERLAYMENT FOR ROOF CLAY TILE | | | INSTALLATION. THIS IS A ROOFING SYSTEM FOR FLAT ROOFS. | | | PROVIDE PRODUCT APPROVAL (2 COPIES) FOR UNDERLAYMENT | | | SYSTEM THAT IS DESIGNED FOR ROOF CLAY TILE | | | INSTALLATION. FAC 61G20-3.001. | | | CLEARLY IDENTIFY WHICH APPROVED UNDERLAYMENT SYSTEM IS | | | GOING TO BE INSTALLED TO VERIFY COMPLIANCE WITH THE | | | DESIGN PRESSURES OF SEC. R301.1 FBC-RESIDENTIAL. , | | | NOTE: IF THE SELECTED ASSEMBLY DOESN'T MEET THE DESIGN | | | PRESSURES FOR ALL ROOF ZONES, THEN SIGNED AND SEALED | | | RAS 117 CALCULATIONS ARE REQUIRED. | | | | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | |
|