| 2018-07-16 09:29:38 | ****CORRECTIONS**** | | | | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | FBC 107.2.1; THE SUBMITTED PLANS DETAIL 3/8"X 6" LAG | | | BOLTS SUPPORTING LEDGER BOARDS INTO THE EXTERIOR BLOCK | | | WALL. PLEASE PROVIDE SPECIFIC DETAILED INFORMATION | | | INCLUDING: DEPTH OF BOLT EMBEDMENT, TYPE OF BOLT | | | COMPATIBLE WITH CONCRETE/MASONRY ANCHORING, AND | | | EDGE/SEPERATION DISTANCE ON THE ANCHORING OF LEDGER | | | BOARDS INTO MASONRY/CONCRETE WALL. |
|