2018-07-07 10:41:16****CORRECTIONS****
  
 PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 FBC107
  
 1. PLEASE SUBMIT MULLION N.O.A. TO BE USED.
  
 NOTE: TYPICALLY IN THIS LOCATION, THE KNEE WALL BELOW
 THE WINDOWS DOES NOT HAVE THE STRUCTURAL CAPACITY TO
 TRANSFER THE LOAD FROM THE MULLION TO THE CONCRETE DECK
 BELOW AS PER PRODUCT APPROVALS AND THE BUILDING CODE.
 PLEASE CONSIDER USING A LONGER MULLION TO ATTACH
 DIRECTLY TO THE ONCRETE DECK BELOW.
  
 2. PLEASE PROVIDE A FLOOR LAYOUT SHOWING WINDOW
 LOCATIONS.
  
 3. THE WORKERS COMP. AND INSURANCE HAVE EXPIRED. PLEASE
 UPDATE.
  