| 2018-07-23 13:08:21 | 1) SUBMIT TOTAL DYNAMIC HEAD CALCULATIONS FOR THE |
| | MAXIMUM SYSTEM FLOW. THE MAXIMUM FLOW OF THE PUMP FROM |
| | ITS PUMP CURVE IS NO LONGER ALLOWED TO BE USED IN |
| | DETERMINING MAXIMUM SYSTEM FLOW RATE PER ANSI/APSP/ICC |
| | 7 - 2013 SECS. 4.4.9, 4.4.9.1. THE 2013 EDITION |
| | ADDRESSES FLOW RATE IN GALLONS PER MINUTE (GPM). IT |
| | REQUIRES THAT MAXIMUM SYSTEM FLOW RATE DOES NOT EXCEED |
| | THE LISTED MAXIMUM FLOW RATE OF THE SUCTION OUTLET |
| | FITTING ASSEMBLY (DRAIN COVER).THE TDH CALCULATIONS |
| | MUST INCLUDE ALL OF THE SYSTEM COMPONENTS IN THE PIPING |
| | SYSTEM INCLUDING THE FILTER. |
| | 2) SUBMIT TWO LEGIBLE COPIES OF THE POOL PUMP CURVE. |
| | IDENTIFY ON THE PUMP CURVE WHICH CURVE KEY IS SPECIFIC |
| | TO THE PUMP BEING INSTALLED ON THIS POOL. THIS IS |
| | NEEDED TO CONFIRM THE MAXIMUM SYSTEM FLOW FROM THE TDH |
| | CALCULATIONS. |
| | 3) INDICATE ON THE POOL PUMP SPECS WHICH PUMP IS BEING |
| | INSTALLED. WPB AMEND. TO FBC SEC. 107.2.1. |
| | 4) SHT. 4 OF 4 - PLEASE REVISE NOTES #7 & #8 - |
| | REFERENCE IS MADE TO 2017 FBCR SEC. R 4101.6.6. THIS |
| | SECTION HAS NOTHING TO DO WITH SWIMMING POOLS. |
| | 5) SHTS.1 & 2 - THERE IS A NOTE IN THE UPPER LEFT |
| | CORNER OF THE SHEET NOTING THAT THE POOL PIPING HAS |
| | BEEN DESIGNED BASED ON THE MAXIMUM FLOW CAPACITY OF THE |
| | SWIMMING POOL PUMP. THIS DESIGN IS NO LONGER PERMITTED |
| | BY APSP-7 2013. |
| | |
| | TIM LARGE |
| | CHIEF PLUMBING INSPECTOR |
| | PLUMBING PLAN REVIEW |
| | 561-805-6692 |
| | [email protected] |
| | |
| | |