| Date |
Text |
| 2018-08-21 13:17:48 | ****CORRECTIONS**** |
| | W.P.B. PERMIT: 18070117 |
| | REVIEWED: AUGUST 20, 2018 |
| | |
| | DYLAN BATTLES |
| | BUILDING PLANS EXAMINER I |
| | [email protected] |
| | 561-805-6718 |
| | |
| | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) |
| | FBC EB = FBC EXISTING BUILDING |
| | FBC R = FBC RESIDENTIAL |
| | |
| | 1. [FBC R107]PROVIDE SURVEY OF PROPERTY. |
| | |
| | 2. [FBC AMENDED 107]ADD ROOF PITCH TO PLANS. |
| | |
| | 3. [FBC AMENDEDWHAT IS EXISTING ROOFING MATERIAL, AND |
| | WHAT IS PROPOSED? |
| | |
| | 4. WHAT ARE THE LOADS ON NEW ROOF? |
| | |
| | 5. [FBC R301.2.1] WIND DESIGN CRITERIA. PROVIDE DESIGN |
| | PRESSURES FOR WINDOW AND DOOR. |
| | PAGE 1 OF WINDOW AND DOOR PRODUCT APPROVALS ARE IN |
| | PERMIT, BUT PLEASE PROVIDE THE FULL PRODUCT APPROVAL |
| | FOR EACH. |
| | |
| | 6. [FBC R803.2.3.1]SHEATHING FASTENING. |
| | SHEATHING NAILS TO BE RING SHANK RSRS01(2 3/8 X 0.113) |
| | PROVIDE PRODUCT APPROVALS FOR ROOFING, OR INDICATE THAT |
| | THEY WILL BE DEFFERED. |
| | |
| | 7. [FBC R318.1] TERMITE PROTECTION. |
| | TERMITE PROTECTION SHALL BE PROVIDED BY REGISTERED |
| | TERMITICIDES, INCLUDING SOIL APPLIED PESTICIDES, |
| | BAITING SYSTEMS, AND PESTICIDES APPLIED TO WOOD, OR |
| | OTHER APPROVED METHODS OF TERMITE PROTECTION LABELED |
| | FOR USE AS A PREVENTATIVE TREATMENT TO NEW |
| | CONSTRUCTION. SEE SECTION 202, ?REGISTERED |
| | TERMITICIDE.? UPON COMPLETION OF THE APPLICATION OF THE |
| | TERMITE PROTECTIVE TREATMENT, A CERTIFICATE OF |
| | COMPLIANCE SHALL BE ISSUED TO THE BUILDING DEPARTMENT |
| | BY THE LICENSED PEST CONTROL COMPANY THAT CONTAINS THE |
| | FOLLOWING STATEMENT: ?THE BUILDING HAS RECEIVED A |
| | COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN |
| | TERMITES. TREATMENT IS IN ACCORDANCE WITH RULES AND |
| | LAWS ESTABLISHED BY THE FLORIDA DEPARTMENT OF |
| | AGRICULTURE AND CONSUMER SERVICES.? |
| | |
| | 8. [FBC R107]PROVIDE WALL TYPE DETAIL. I SEE 2X6 WALL |
| | WITH 19/32 CDX, BUT WHAT ARE THE FINISHES ON INTERIOR |
| | AND EXTERIOR OVER THE PLYWOOD? |
| | |
| | 9. [FBC R806]WHAT TYPE OF INSULATION IS BEING INSTALLED |
| | IN THE NEW ATTIC, AND HOW IS IT VENTED? |
| | |
| | NOTE: |
| | -PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW |
| | EACH COMMENT IS BEING ADDRESSED. |
| | -ADDITIONAL COMMENTS MAY BE FORTHCOMING PENDING REVIEW |
| | OF MATERIALS REQUESTED. |
| | -WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS |
| | OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS) |
| | SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT |
| | DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER |
| | SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID" |
| | OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS |
| | APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE |
| | NEED "VOID", RENDERING THEM NOT USABLE. |
| | |