| 2019-01-24 13:25:23 | PROVISO: | | | SUBMITTAL FOR METAL STAIR, HANDRAIL AND GUARDS TO BE | | | PROVIDED . | | | | | | ASCE 7-10 SECTION 4.5.1 LOADS ON HANDRAIL AND GUARDRAIL | | | SYSTEMS. ALL HANDRAIL AND GUARDRAIL SYSTEMS SHALL BE | | | DESIGNED TO ESIST A SINGLE CONCENTRATED LOAD OF 200 LB | | | APPLIED IN ANY DIRECTION AT ANY POINT ON THE HANDRAIL | | | OR TOP RAIL AND TO TRANSFER THIS LOAD THROUGH THE | | | SUPPORTS TO THE STRUCTURE. FURTHER, ALL HANDRAILS AND | | | GUARDRAIL SYSTEMS SHALL BE DESIGNED TO RESIST A LOAD OF | | | 50 POUND-FORCE PER LINEAR FOOT APPLIED IN ANY DIRECTION | | | ALONG THE HANDRAIL OR TOP RAIL. |
|