| Date |
Text |
| 2018-08-10 14:15:06 | ****CORRECTIONS**** |
| | W.P.B. PERMIT: 18061260 |
| | REVIEWED: AUGUST 10, 2018 |
| | |
| | DYLAN BATTLES |
| | BUILDING PLANS EXAMINER |
| | [email protected] |
| | 561-805-6718 |
| | |
| | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) |
| | FBC EC = FBC ENERGY CONSERVATION |
| | FBC R = FBC RESIDENTIAL |
| | |
| | 1. [FBC R401.4]PROVIDE SOIL REPORT TO SHOW BEARING |
| | CAPACITY AND FOUNDATION RECOMMENDATION FOR 2 STORY |
| | STRUCTURE. |
| | |
| | 2. [FBC ENERGY TABLE R402A]FLOOR BETWEEN GARAGE SHOULD |
| | BE R13. PLEASE ADD TO ENERGY FORM R402-2017. |
| | |
| | 3. RE-PRINT 2 COPIES OF FL5684-R8. THE COPIES PROVIDED |
| | AREN?T LEDGIBLE AFTER THE FIRST COUPLE OF PAGES. |
| | |
| | 4. [FBC R905.2.2] [FBC R905.1.1]FOR ROOF SLOPES FROM |
| | TWO UNITS VERTICAL IN 12 UNITS HORIZONTAL (2:12) AND |
| | LESS THAN FOUR UNITS VERTICAL IN 12 UNITS HORIZONTAL |
| | (4:12), DOUBLE UNDERLAYMENT APPLICATION IS REQUIRED. |
| | |
| | 5. [R302.6]GARAGE CEILING TO HAVE TYPE NOT LESS THAT |
| | 5/8? TYPE X OR EQUIVELANT DRYWALL WHEN HABITABLE SPACE |
| | IS PROVIDED ABOVE. |
| | |
| | 6. [FBC R506.2.3] A 6-MIL (0.006 INCH; 152 ?M) |
| | POLYETHYLENE OR APPROVED VAPOR RETARDER WITH JOINTS |
| | LAPPED NOT LESS THAN 6 INCHES. |
| | |
| | PROVISO: |
| | PROVIDE ROOF TRUSS ENGINEERING SUBMITTAL PRIOR TO |
| | INSTALLATION. |
| | PROVIDE STAIR AND RAIL ENGINEERING SUBMITTAL PRIOR TO |
| | INSTALLATION. |
| | |
| | NOTE: |
| | -PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW |
| | EACH COMMENT IS BEING ADDRESSED. |
| | -ADDITIONAL COMMENTS MAY BE FORTHCOMING PENDING REVIEW |
| | OF MATERIALS REQUESTED. |
| | -WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS |
| | OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS) |
| | SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT |
| | DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER |
| | SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID" |
| | OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS |
| | APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE |
| | NEED "VOID", RENDERING THEM NOT USABLE. |
| | |