| 2018-10-30 15:00:14 | ****CORRECTIONS**** |
| | W.P.B. PERMIT: 18061145 |
| | |
| | DYLAN BATTLES |
| | BUILDING PLANS EXAMINER |
| | [email protected] |
| | 561-805-6718 |
| | |
| | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) |
| | FBC B = FBC BUILDING |
| | FBC EB = FBC EXISTING BUILDING |
| | FBC A = FBC ACCESSIBILITY |
| | FBC EC = FBC ENERGY CONSERVATION |
| | FBC R = FBC RESIDENTIAL |
| | |
| | 1. AN ADDRESS WILL NEED TO BE PROVIDED FOR LOT 42. |
| | FOR ADDRESSING, PLEASE CONTACT (PREFERABLY VIA EMAIL): |
| | MICHAEL ORIO |
| | GIS SUPPORT SPECIALIST |
| | [email protected] |
| | CITY OF WEST PALM BEACH |
| | INFORMATION TECHNOLOGY DEPARTMENT |
| | 401 CLEMATIS STREET, WEST PALM BEACH, FLORIDA 33401 |
| | P: 561.494.1080 |
| | |
| | 1-2. PROVIDE DOCUMENTATION THAT THE PROPERTY HAS BEEN |
| | SUB DIVIDED WITH THE PALM BEACH COUNTY PROPERTY |
| | APPRAISER?S OFFICE. |
| | ALSO, PROVIDE THE NEW ADDRESS AND PUT IT ON THE |
| | DRAWINGS IF CHANGED FROM 1113 22ND. |
| | |
| | 2. OK |
| | |
| | 3. OK |
| | |
| | 4. [FBC R401.3]PROVIDE SITE DRAINAGE PLAN. ALSO PROVIDE |
| | THE LOWEST FLOOR ELEVATION ON RELEVANT DRAWINGS. THIS |
| | SHOULD BE USED IN CONJUCTION WITH DRAINAGE PLAN TO SHOW |
| | GRADE 4" LOWER THAN LOWEST FLOOR LEVEL AND HOW DRAINAGE |
| | MEETS REQUIREMENTS IN [FBC R401.3] |
| | |
| | 4-2. SITE DRAINAGE PROVIDED DOESN?T KEEP THE DRAINAGE |
| | WITHIN THE SITE. |
| | [FBC R403.1.7.3] FOUNDATION ELEVATION. |
| | ON GRADED SITES, THE TOP OF ANY EXTERIOR FOUNDATION |
| | SHALL EXTEND ABOVE THE ELEVATION OF THE STREET GUTTER |
| | AT POINT OF DISCHARGE OR THE INLET OF AN APPROVED |
| | DRAINAGE DEVICE A MINIMUM OF 12 INCHES (305 MM) PLUS 2 |
| | PERCENT. ALTERNATE ELEVATIONS ARE PERMITTED SUBJECT TO |
| | THE APPROVAL OF THE BUILDING OFFICIAL, PROVIDED IT CAN |
| | BE DEMONSTRATED THAT REQUIRED DRAINAGE TO THE POINT OF |
| | DISCHARGE AND AWAY FROM THE STRUCTURE IS PROVIDED AT |
| | ALL LOCATIONS ON THE SITE. |
| | |
| | 5. OK |
| | |
| | 6. OK |
| | |
| | 7. [FBC ENERGY R401.2]PROVIDE ENERGY CALCULATIONS TO |
| | MEET REQUIREMENTS IN R401.2 RESIDENTIAL ENERGY CODE. |
| | CHOOSE METHOD IN R401.2 AND SUPPLY DOCUMENTATION. |
| | |
| | 7-2 ENERGY CODE COMPLIANCE NEEDS TO BE MET FOR BUILDING |
| | AS WELL AS MECHANICAL. IF PERFORMANCE BASED ENERGY |
| | CALCULATIONS AREN?T PROVIDED THAN INDICATE THE METHOD |
| | USED TO COMPLY FOR ALL BUILDING ELEMENTS AS APPLICABLE |
| | TO [FBC ENERGY R401.2] |
| | |
| | 8. OK |
| | |
| | 9. OK |
| | |
| | 10. PRODUCT APPROVALS WILL BE A PROVISO TO THE PERMIT. |
| | |
| | 11. PRODUCT APPROVALS FOR ROOFING TO BE SUBMITTED WITH |
| | THE SUB-PERMIT FOR ROOFING. |
| | |
| | 12. OK |
| | |
| | 13. OK |
| | |
| | 14. OK |
| | |
| | PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW |
| | EACH COMMENT IS BEING ADDRESSED. |
| | |
| | NOTE: |
| | ADDITIONAL COMMENTS MAY BE FORTHCOMING PENDING REVIEW |
| | OF MATERIALS REQUESTED. |
| | WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS |
| | OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS) |
| | SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT |
| | DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER |
| | SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID" |
| | OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS |
| | APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE |
| | NEED "VOID", RENDERING THEM NOT USABLE. |
| | |
| | |