2018-10-30 15:00:14****CORRECTIONS****
 W.P.B. PERMIT: 18061145
  
 DYLAN BATTLES
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6718
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 1. AN ADDRESS WILL NEED TO BE PROVIDED FOR LOT 42.
 FOR ADDRESSING, PLEASE CONTACT (PREFERABLY VIA EMAIL):
 MICHAEL ORIO
 GIS SUPPORT SPECIALIST
 [email protected]
 CITY OF WEST PALM BEACH
 INFORMATION TECHNOLOGY DEPARTMENT
 401 CLEMATIS STREET, WEST PALM BEACH, FLORIDA 33401
 P: 561.494.1080
  
 1-2. PROVIDE DOCUMENTATION THAT THE PROPERTY HAS BEEN
 SUB DIVIDED WITH THE PALM BEACH COUNTY PROPERTY
 APPRAISER?S OFFICE.
 ALSO, PROVIDE THE NEW ADDRESS AND PUT IT ON THE
 DRAWINGS IF CHANGED FROM 1113 22ND.
  
 2. OK
  
 3. OK
  
 4. [FBC R401.3]PROVIDE SITE DRAINAGE PLAN. ALSO PROVIDE
 THE LOWEST FLOOR ELEVATION ON RELEVANT DRAWINGS. THIS
 SHOULD BE USED IN CONJUCTION WITH DRAINAGE PLAN TO SHOW
 GRADE 4" LOWER THAN LOWEST FLOOR LEVEL AND HOW DRAINAGE
 MEETS REQUIREMENTS IN [FBC R401.3]
  
 4-2. SITE DRAINAGE PROVIDED DOESN?T KEEP THE DRAINAGE
 WITHIN THE SITE.
 [FBC R403.1.7.3] FOUNDATION ELEVATION.
 ON GRADED SITES, THE TOP OF ANY EXTERIOR FOUNDATION
 SHALL EXTEND ABOVE THE ELEVATION OF THE STREET GUTTER
 AT POINT OF DISCHARGE OR THE INLET OF AN APPROVED
 DRAINAGE DEVICE A MINIMUM OF 12 INCHES (305 MM) PLUS 2
 PERCENT. ALTERNATE ELEVATIONS ARE PERMITTED SUBJECT TO
 THE APPROVAL OF THE BUILDING OFFICIAL, PROVIDED IT CAN
 BE DEMONSTRATED THAT REQUIRED DRAINAGE TO THE POINT OF
 DISCHARGE AND AWAY FROM THE STRUCTURE IS PROVIDED AT
 ALL LOCATIONS ON THE SITE.
  
 5. OK
  
 6. OK
  
 7. [FBC ENERGY R401.2]PROVIDE ENERGY CALCULATIONS TO
 MEET REQUIREMENTS IN R401.2 RESIDENTIAL ENERGY CODE.
 CHOOSE METHOD IN R401.2 AND SUPPLY DOCUMENTATION.
  
 7-2 ENERGY CODE COMPLIANCE NEEDS TO BE MET FOR BUILDING
 AS WELL AS MECHANICAL. IF PERFORMANCE BASED ENERGY
 CALCULATIONS AREN?T PROVIDED THAN INDICATE THE METHOD
 USED TO COMPLY FOR ALL BUILDING ELEMENTS AS APPLICABLE
 TO [FBC ENERGY R401.2]
  
 8. OK
  
 9. OK
  
 10. PRODUCT APPROVALS WILL BE A PROVISO TO THE PERMIT.
  
 11. PRODUCT APPROVALS FOR ROOFING TO BE SUBMITTED WITH
 THE SUB-PERMIT FOR ROOFING.
  
 12. OK
  
 13. OK
  
 14. OK
  
 PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW
 EACH COMMENT IS BEING ADDRESSED.
  
 NOTE:
 ADDITIONAL COMMENTS MAY BE FORTHCOMING PENDING REVIEW
 OF MATERIALS REQUESTED.
 WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS
 OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS)
 SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT
 DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER
 SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID"
 OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS
 APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE
 NEED "VOID", RENDERING THEM NOT USABLE.
  
  