Plan Review Notes
Plan Review Notes For Permit 18061145
Permit Number 18061145
Review Stop B
Sequence Number 1
Notes
Date Text
2018-07-20 07:57:17****CORRECTIONS****
 W.P.B. PERMIT: 18061145
  
 DYLAN BATTLES
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6718
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 1. AN ADDRESS WILL NEED TO BE PROVIDED FOR LOT 42.
 FOR ADDRESSING, PLEASE CONTACT (PREFERABLY VIA EMAIL):
 MICHAEL ORIO
 GIS SUPPORT SPECIALIST
 [email protected]
 CITY OF WEST PALM BEACH
 INFORMATION TECHNOLOGY DEPARTMENT
 401 CLEMATIS STREET, WEST PALM BEACH, FLORIDA 33401
 P: 561.494.1080
  
 2. IS THIS PROJECT BEING BUILT WITH FEDERAL FUNDS?
 PLEASE VERIFY THAT ADDITIONAL ADA REQUIREMENTS DON'T
 APPLY IF FEDERAL FUNDING IS BEING USED FOR THIS
 PROJECT.
  
 3. [FBC R401.4]PROVIDE SOIL REPORT TO SHOW BEARING
 CAPACITY.
  
 4. [FBC R401.3]PROVIDE SITE DRAINAGE PLAN. ALSO PROVIDE
 THE LOWEST FLOOR ELEVATION ON RELEVANT DRAWINGS. THIS
 SHOULD BE USED IN CONJUCTION WITH DRAINAGE PLAN TO SHOW
 GRADE 4" LOWER THAN LOWEST FLOOR LEVEL AND HOW DRAINAGE
 MEETS REQUIREMENTS IN [FBC R401.3]
  
 5. [FBC 107.3.5.3] PROVIDE SEDIMENT CONTROL PLAN TO
 KEEP CONSTRUCTION DEBRIS FROM ENTERING ADJACENT
 PROPERTIES AND STORM DRAINS.
  
 6. [FBC 107.3.5.3] PLEASE ADD PROJECT DESIGN DATA:
 ZONING, OCCUPANCY, CONSTRUCTION TYPE AND MEAN ROOF
 HEIGHT(MRH).
  
 7. [FBC ENERGY R401.2]PROVIDE ENERGY CALCULATIONS TO
 MEET REQUIREMENTS IN R401.2 RESIDENTIAL ENERGY CODE.
 CHOOSE METHOD IN R401.2 AND SUPPLY DOCUMENTATION.
  
 8. [FBC R302.10]PROVIDE CUT SHEET FOR ICYNENE(SEE
 ICC-ES REPORT OR EQUAL) WITH THE TYPE SELECTED TO
 ESTABLISH THICKNESS NEEDED TO MEET REQUIRED R-VALUE,
 FLAME SPREAD INDEX AND SMOKE DEVELOPED INDEX.
 IF THERE IS MECHANICAL EQUIPMENT IN THE SPACE THAN IT
 REQUIRES IGNITION BARRIER.
  
 9. [FBC R806.5]DETAIL 5/S-3 SHOWS CONTINOUS VENT AT
 SOFFIT. WITH ICYNENE SPRAYED TO UNDERSIDE OF ROOF DECK.
 THE ATTIC SPACE NEEDS TO BE CONTAINED WITHIN THE
 BUILDING ENVELOPE. PLEASE INDICATE IF THIS IS AN
 UNVENTED ATTIC OR EXPLAIN HOW THE VENTS WON'T BREAK THE
 THERMAL ENVELOPE.
  
 10. [FBC 107.2.1.2]PROVIDE PRODUCT APPROVALS FOR
 WINDOWS, WINDOW MULL, DOORS, TRANSOMS, SLIDERS AND
 SOLAR TUBES, OR INDICATE THAT YOU WOULD LIKE THEM
 DEFFERED. THE DEFERRED SUBMITTAL DOCUMENTS SHALL BE
 APPROVED BY THE BUILDING OFFICIAL PRIOR TO
 INSTALLATION.
  
 11. [FBC 107.2.1.2]PROVIDE PRODUCT APPROVALS FOR
 ROOFING, OR INDICATE THAT YOU WOULD LIKE THEM DEFFERED.
 THE DEFERRED SUBMITTAL DOCUMENTS SHALL BE APPROVED BY
 THE BUILDING OFFICIAL PRIOR TO INSTALLATION.
  
 12. [FBC R703.4]PROVIDE NOTE FOR TYPE OF WINDOW/DOOR
 FLASHING TO BE USED TO MEET REQUIREMNETS OF [FBC
 R703.4].
  
 13. [FBC R608.8]PROVIDE LINTEL SCHEDULE TO SHOW
 BEARING. PROVIDE LINTEL DOCUMENTATION FOR SAFE LOADING.
  
 14.[FBC R402.2]DETAIL 5/S3 SAYS CONCRETE COMPRESSIVE
 STRENGTH IS 300. PLEASE UPDATE TO 3000 IF THAT WAS THE
 INTENT. ALSO, ADD COMPRESSIVE STRENGTH FOR GROUT.
  
 PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW
 EACH COMMENT IS BEING ADDRESSED.
  
 NOTE:
 ADDITIONAL COMMENTS MAY BE FORTHCOMING PENDING REVIEW
 OF MATERIALS REQUESTED.
 WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS
 OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS)
 SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT
 DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER
 SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID"
 OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS
 APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE
 NEED "VOID", RENDERING THEM NOT USABLE.
  
  