Plan Review Notes
Plan Review Notes For Permit 18061140
Permit Number 18061140
Review Stop THRESHOLD
Sequence Number 1
Notes
Date Text
2018-08-20 09:10:28110.8 THRESHOLD BUILDING.
  
 110.8.1 THE ENFORCING AGENCY SHALL REQUIRE A SPECIAL
 INSPECTOR TO PERFORM STRUCTURAL
 INSPECTIONS ON A THRESHOLD BUILDING PURSUANT TO A
 STRUCTURAL INSPECTION PLAN PREPARED BY THE
 ENGINEER OR ARCHITECT OF RECORD. THE STRUCTURAL
 INSPECTION PLAN MUST BE SUBMITTED TO THE
 ENFORCING AGENCY PRIOR TO THE ISSUANCE OF A BUILDING
 PERMIT FOR THE CONSTRUCTION OF A
 THRESHOLD BUILDING. THE PURPOSE OF THE STRUCTURAL
 INSPECTION PLANS IS TO PROVIDE SPECIFIC
 INSPECTION PROCEDURES AND SCHEDULES SO THAT THE
 BUILDING CAN BE ADEQUATELY INSPECTED FOR
 COMPLIANCE WITH THE PERMITTED DOCUMENTS. THE SPECIAL
 INSPECTOR MAY NOT SERVE AS A
 SURROGATE IN CARRYING OUT THE RESPONSIBILITIES OF THE
 BUILDING OFFICIAL, THE ARCHITECT OR THE
 ENGINEER OF RECORD. THE CONTRACTOR'S CONTRACTUAL OR
 STATUTORY OBLIGATIONS ARE NOT RELIEVED BY
 ANY ACTION OF THE SPECIAL INSPECTOR.
  
 110.8.2 THE SPECIAL INSPECTOR SHALL DETERMINE THAT A
 PROFESSIONAL ENGINEER WHO
 SPECIALIZES IN SHORING DESIGN HAS INSPECTED THE SHORING
 AND RESHORING FOR CONFORMANCE WITH
 THE SHORING AND RESHORING PLANS SUBMITTED TO THE
 ENFORCING AGENCY. A FEE SIMPLE TITLE OWNER
 OF A BUILDING, WHICH DOES NOT MEET THE MINIMUM SIZE,
 HEIGHT, OCCUPANCY, OCCUPANCY
 CLASSIFICATION OR NUMBER-OF-STORIES CRITERIA WHICH
 WOULD RESULT IN CLASSIFICATION AS A THRESHOLD
 BUILDING UNDER S. 553 .71(12), MAY DESIGNATE SUCH
 BUILDING AS A THRESHOLD BUILDING, SUBJECT
 TO MORE THAN THE MINIMUM NUMBER OF INSPECTIONS REQUIRED
 BY THE FLORIDA BUILDING CODE.
 45
 CITY OF WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, 6TH EDITION (2017)
 110.8.3 THE FEE OWNER OF A THRESHOLD BUILDING SHALL
 SELECT AND PAY ALL COSTS OF
 EMPLOYING A SPECIAL INSPECTOR, BUT THE SPECIAL
 INSPECTOR SHALL BE RESPONSIBLE TO THE
 ENFORCEMENT AGENCY. THE INSPECTOR SHALL BE A PERSON
 CERTIFIED, LICENSED OR REGISTERED
 UNDER CHAPTER 471, FLORIDA STATUTES, AS AN ENGINEER OR
 UNDER CHAPTER 481, FLORIDA
 STATUTES, AS AN ARCHITECT.
  
 110.8.4 EACH ENFORCEMENT AGENCY SHALL REQUIRE THAT, ON
 EVERY THRESHOLD BUILDING:
  
 110.8.4.1 THE SPECIAL INSPECTOR, UPON COMPLETION OF THE
 BUILDING AND PRIOR TO THE
 ISSUANCE OF A CERTIFICATE OF OCCUPANCY, FILE A SIGNED
 AND SEALED STATEMENT WITH THE
 ENFORCEMENT AGENCY IN SUBSTANTIALLY THE FOLLOWING FORM:
 "TO THE BEST OF MY KNOWLEDGE
 AND BELIEF, THE ABOVE DESCRIBED CONSTRUCTION OF ALL
 STRUCTURAL LOAD-BEARING COMPONENTS
 COMPLIES WITH THE PERMITTED DOCUMENTS, AND THE SHORING
 AND RESHORING CONFORMS TO THE
 SHORING AND RESHORING PLANS SUBMITTED TO THE
 ENFORCEMENT AGENCY."
  
 110.8.4.2 ANY PROPOSAL TO INSTALL AN ALTERNATE
 STRUCTURAL PRODUCT OR SYSTEM TO WHICH
 BUILDING CODES APPLY SHALL BE SUBMITTED TO THE
 ENFORCEMENT AGENCY FOR REVIEW FOR
 COMPLIANCE WITH THE CODES AND MADE PART OF THE
 ENFORCEMENT AGENCY'S RECORDED SET OF
 PERMIT DOCUMENTS.
  
 110.8.4.3 ALL SHORING AND RESHORING PROCEDURES, PLANS
 AND DETAILS SHALL BE
 SUBMITTED TO THE ENFORCEMENT AGENCY FOR RECORDKEEPING.
 EACH SHORING AND RESHORING
 INSTALLATION SHALL BE SUPERVISED, INSPECTED AND
 CERTIFIED TO BE IN COMPLIANCE WITH THE
 SHORING DOCUMENTS BY THE CONTRACTOR .
  
 110.8.4.4 ALL PLANS FOR THE BUILDING WHICH ARE REQUIRED
 TO BE SIGNED AND SEALED
 BY THE ARCHITECT OR ENGINEER OF RECORD CONTAIN A
 STATEMENT THAT, TO THE BEST OF THE
 ARCHITECT'S OR ENGINEER'S KNOWLEDGE, THE PLANS AND
 SPECIFICATIONS COMPLY WITH THE
 APPLICABLE MINIMUM BUILDING CODES AND THE APPLICABLE
 FIRE-SAFETY STANDARDS AS
 DETERMINED BY THE LOCAL AUTHORITY IN ACCORDANCE WITH
 THIS SECTION AND CHAPTER 633.
 FLORIDA STATUTES.
  
 110.8.5 NO ENFORCING AGENCY MAY ISSUE A BUILDING PERMIT
 FOR CONSTRUCTION OF ANY
 THRESHOLD BUILDING EXCEPT TO A LICENSED GENERAL
 CONTRACTOR, AS DEFINED IN SECTION
 489.105(3) (A), FLORIDA STATUTES, OR TO A LICENSED
 BUILDING CONTRACTOR, AS DEFINED IN SECTION
 489. 105(3) (B), FLORIDA STATUTES, WITHIN THE SCOPE OF
 HER OR HIS LICENSE. THE NAMED
 CONTRACTOR TO WHOM THE BUILDING PERMIT IS ISSUED SHALL
 HAVE THE RESPONSIBILITY FOR
 SUPERVISION, DIRECTION, MANAGEMENT AND CONTROL OF THE
 CONSTRUCTION ACTIVITIES ON THE
 PROJECT FOR WHICH THE BUILDING PERMIT WAS ISSUED.
 110.8.6 THE BUILDING DEPARTMENT MAY ALLOW A SPECIAL
 INSPECTOR TO CONDUCT THE MINIMUM
 STRUCTURAL INSPECTION OF THRESHOLD BUILDINGS REQUIRED
 BY THIS CODE, SECTION 553.73, FLORIDA
 STATUTES, WITHOUT DUPLICATIVE INSPECTION BY THE
 BUILDING DEPARTMENT. THE BUILDING OFFICIAL IS
 RESPONSIBLE FOR ENSURING THAT ANY PERSON CONDUCTING
 INSPECTIONS IS QUALIFIED AS A BUILDING
 INSPECTOR UNDER PART XII OF CHAPTER 468, FLORIDA
 STATUTES, OR CERTIFIED AS A SPECIAL INSPECTOR
 UNDER CHAPTER 471 OR 481, FLORIDA STATUTES. INSPECTIONS
 OF THRESHOLD BUILDINGS REQUIRED BY
 SECTION 553.79(5), FLORIDA STATUTES, ARE IN ADDITION TO
 THE MINIMUM INSPECTIONS REQUIRED BY THIS CODE.
  