| Plan Review Notes For Permit 18061038 |
| Permit Number |
18061038 |
|
| Review Stop |
B |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2018-12-11 08:54:51 | PROVISOS: | | | | | | 1) ELEVATION CERTIFICATE | | | A. THIS PARCEL IS LOCATED IN A SPECIAL FLOOD HAZARD | | | AREA; FLOOD MAP IN EFFECT AT TIME OF FOUNDATION PERMIT | | | APPLICATION 1979 FIRMS + 2' FREEBOARD; MINIMUM | | | ELEVATION = 9.0' NAV88, PROPOSED LOWEST FINISHED FLOOR | | | ELEVATION = 9.0' NAV88. | | | A "BUILDING UNDER CONSTRUCTION" ELEVATION CERTIFICATE | | | OR FORM BOARD SURVEY IS REQUIRED PRIOR TO CONCRETE | | | POUR. THIS MAY BE SENT VIA EMAIL FOR PRELIMINARY REVIEW | | | A "FINISHED CONSTRUCTION" ELEVATION CERTIFICATE IS | | | REQUIRED PRIOR TO FINAL INSPECTION AND/OR CO AND/OR | | | TCO. | | | | | | 2) [FBC AMENDED 107.3.4.1]PROVIDE PRODUCT APPROVALS FOR | | | WINDOWS, WINDOW MULL, DOORS, TRANSOMS, SLIDERS AND | | | SOLAR TUBES AS A SUBMITTAL. | | | | | | 3) [FBC AMENDED 107.2.1.2]PROVIDE STAIRCASE AND GUARD | | | RAIL ENGINEERING AS A SUBMITTAL. | | | | | | 4) [FBC AMENDED 107.3.4.1]SUBMIT TRUSS SHOP DRAWINGS TO | | | THE BUILDING INSPECTOR PRIOR TO INSTALLATION. |
|