Plan Review Notes
Plan Review Notes For Permit 18061038
Permit Number 18061038
Review Stop B
Sequence Number 1
Notes
Date Text
2018-07-14 10:42:40****CORRECTIONS****
 W.P.B. PERMIT: 18061038 (MAIN HOUSE)
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 IMPACT FEES WILL APPLY
  
 1. [107.3.5.3.1]PROVIDE "CONSTRUCTION DOCUMENTS"
 ELEVATION CERTIFICATE WITH DESIGN FLOOD ELEVATIONS TO
 INCLUDE ANY MECHANICAL EQUIPMENT AS APPLICABLE.
  
 2. [FBC R322.2.1]THE CITY OF WPB HAS ADOPTED A 2?
 FREEBOARD ABOVE B.F.E. SEE AMENDMENT TO FBC R322.2.1 IN
 ORD. NO. 4765-18, ? 2, 3-12-2018(SEC 18-33). SEE
 COMMENTS REGARDING FLOOD VENTS.
  
 3. [FBC R107.2.5]PROVIDE SURVEY OF PROPERTY.
  
 4. [FBC R401.4]PROVIDE SOIL REPORT TO SHOW BEARING
 CAPACITY.
  
 5. [FBC R401.3]PROVIDE SITE DRAINAGE PLAN. THE COVER
 SHEETS CALL FOR C-1, C-2 & EC-1. THESE SHEETS ARE NOT
 PROVIDED SO I CANNOT REVIEW THE DRAINAGE AT THIS TIME.
 PLEASE PROVIDE MISSING SHEETS TO SHOW DRAINAGE PLAN.
  
 6. [FBC 107.2.1.2]PROVIDE PRODUCT APPROVALS FOR
 WINDOWS, WINDOW MULL, DOORS, TRANSOMS, SLIDERS AND
 SOLAR TUBES, OR INDICATE THAT YOU WOULD LIKE THEM
 DEFFERED. THE DEFERRED SUBMITTAL DOCUMENTS SHALL BE
 APPROVED BY THE BUILDING OFFICIAL PRIOR TO
 INSTALLATION.
  
 7. [FBC 107.2.1.2]PROVIDE PRODUCT APPROVALS FOR
 ROOFING, OR INDICATE THAT YOU WOULD LIKE THEM DEFFERED.
 THE DEFERRED SUBMITTAL DOCUMENTS SHALL BE APPROVED BY
 THE BUILDING OFFICIAL PRIOR TO INSTALLATION.
  
 8. [FBC 107.2.1.2]OTHER DEFFRRED SUBMITTALS INCLUDE
 STAIRCASES, GUARD RAILS AND TRUSS PACKAGE.
  
 9. [FBC ENERGY R401.2]PROVIDE ENERGY CALCULATIONS TO
 MEET REQUIREMENTS IN R401.2 RESIDENTIAL ENERGY CODE.
 CHOOSE METHOD IN R401.2 AND SUPPLY DOCUMENTATION.
  
 10. NO ENERGY CALCULATIONS PROVIDED, SO I BELIEVE YOU
 ARE GOING WITH PRESCIPTIVE. PLEASE FOLLOW ALL
 RESIDENTIAL ENEGRY CODE SECTIONS R410-R404 AND INDICATE
 ON PLANS HOW YOU ARE MEETING THE CODE.
 BELOW ARE SOME, BUT NOT ALL, APPLICABLE ITEMS FOR
 REFERENCE.
 [R401.3]ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD.
 [R402.2.4]ACCESS HATCHES AND DOORS.
 [R402.3.2]GLAZED FENESTRATION SHGC
 [TABLE R402.1.2]ASSIGN R-VALUES FROM THIS TABLE FOR
 MASS WALLS AND FLOOR(GARAGE/STORAGE ABV.)
  
 11. [FBC ENERGY TABLE R402.1.2]THE ENERGY CODE REQUIRES
 MINIMUM R-30 AT CEILING.
 [FBC R302.10]PROVIDE CUT SHEET FOR ICYNENE(SEE ESR-3458
 OR EQUAL) WITH THE TYPE SELECTED TO ESTABLISH THICKNESS
 NEEDED TO MEET REQUIRED R-VALUE, FLAME SPREAD INDEX AND
 SMOKE DEVELOPED INDEX.
 [FBC 2603.4.1.6]PROVIDE IGNITION BARRIER FOR AIR
 HANDLERS IN ATTIC SPACE WHERE ICYNENE IS PRESENT.
  
 12. [FBC R807]SHOW LOCATION AND SIZE OF ATTIC ACCESS ON
 PLANS.
  
 13. [FBC R322.2.2]SHOW FLOOD VENT CALCULATIONS FOR
 GARAGE. PAGE M1.1 STATES THAT THESE VENTS ARE 12" OFF
 THE GROUND. FOLLOW R322.2.2.1 FOR INSTALLATION HEIGHTS
 OF FLOOD VENTS. ENGINEERING, CALCULATION, OR PRODUCT
 APPROVAL REQUIRED.
  
 14. [FBC R312.2]WINDOW FALL PROTECTION. INDICATE ON
 PLANS WHERE THIS IS APPLICABLE. IT LOOKS LIKE THE
 WINDOWS ABOVE GARAGE S-1/A302 NEED PROTECTION, BUT I
 CANT TELL IN THE MAIN HOUSE BEDROOMS. SECTION S-4/A303
 DOESN'T SHOW WINDOW HEIGHT IN BEDROOM.
  
 15. [FBC R1001.1]PROVIDE CHIMENY DETAILS TO SHOW
 COMPLIANCE WITH CHAPTER 10 FOR RESIDENTIAL CHIMENY
 SHOWN ON SOUTH LIVING ROOM WALL. IS THE NORTH CHIMENY
 FUNCTIONAL?
  
 16. [FBC R803.2.3.1]SHEATHING FASTENING ON 2/S4 CALLS
 FOR 10D, BUT SHEATHING NAILS NEED TO BE RING SHANK
 RSRS01(2 3/8 X 0.113)
  
 17. [FBC 107.2.5]HOW DOES AHU #5 WORK IN THIS OPEN
 STAIR AREA? IT APPEARS TO BE IN THE 1ST FLOOR STORAGE
 UNDER STAIRS. DUCTS GO OUT FROM THERE, BUT THERE IS NO
 ATTIC SPACE IN THE STAIR OPENING. PLEASE UPDATE TO SHOW
 HOW AHU #5 WILL FIT IN SPACE PROVIDED.
 ALSO, AHU #4 LOOKS LIKE IT IS ON A STAND IN THE 2ND
 FLOOR STORAGE. IT SHOWS THAT IT IS A SMALL CLOSET WITH
 RETURN ON THE WALL. PLEASE SHOW THIS CLOSET ON OTHER
 DRAWINGS FOR SIZING, OR ADJUST AHU #4 ACCORDINGLY TO
 HOW IT IS PLACED.
  
 18. THIS PERMIT WILL BE ISSUED WITH PROVISO:
 A "BUILDING UNDER CONSTRUCTION" ELEVATION CERTIFICATE
 IS REQUIRED PRIOR TO CONCRETE POUR
 A "FINISHED CONSTRUCTION" ELEVATION CERTIFICATE IS
 REQUIRED PRIOR TO C.O.
  
 NOTE:
 A RESPONSE LETTER IS HELPFUL TO EXPEDITE PLAN REVIEW.
  
 WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS
 OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS)
 SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT
 DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER
 SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID"
 OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS
 APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE
 NEED "VOID", RENDERING THEM NOT USABLE.
  
  
  
  
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved