| Plan Review Notes For Permit 18060684 |
| Permit Number |
18060684 |
|
| Review Stop |
P |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2018-11-29 13:57:38 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION | | | FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH | | | EDITION | | | FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION | | | FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION | | | FAC= FLORIDA ADMINISTRATIVE CODE | | | FS = FLORIDA STATUTES | | | | | | PLUMBING COMMENTS: DENIED | | | | | | 1. RESPONCE TO ITEM #2 OF THE 1ST REVIEW IS STILL | | | INCORRECT. DRY VENTS MUST RISE VERTICALLY FROM THE | | | DRAIN BEING VENTED PER FBC RES P3104.3 AND | | | P3404.4.PROVIDE A CORRECTED PLUMBING ISOMETRIC REMOVING | | | THE FLAT DRYVENTS AND ONLY SHOWING WET VENTING AS | | | REQUIRED FBC RES P3108.1 | | | | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | PHONE 561-805-6715 | | | |
|