| 2019-03-27 13:22:56 | BUILDING PLAN REVIEW - ROOFING |
| | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST |
| | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, |
| | CHAPTER 1 ADMINISTRATION |
| | |
| | CHRISTOPHER S. THROOP, C.B.O. |
| | BUILDING PLANS EXAMINER, PX3169 |
| | 1&2 FAMILY PLANS EXAMINER, SFP306 |
| | CONSTRUCTION SERVICES DIVISION |
| | TEL: 561-805-6726 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | 2ND REVIEW |
| | RESULTS: DENIED |
| | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED |
| | BELOW. |
| | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| | |
| | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED |
| | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS |
| | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY |
| | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW |
| | COMMENT WILL BE LISTED AFTER PREVIOUS COMMENTS. |
| | |
| | 1. PROVIDE PRODUCT APPROVALS FOR ROOFING SYSTEM |
| | COMPONENTS. (STANDING SEAM METAL ROOF) - NOT ADDRESSED |
| | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE |
| | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED |
| | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. |
| | SPECIFICALLY, PROVIDE ROOFING SUBMITTALS. |
| | |
| | 2. PER AISI STANDARD S100-2007-C THE FOLLOWING MAY |
| | APPLY: - NOT ADDRESSED |
| | D6.2.1A STRENGTH (RESISTANCE) OF STANDING SEAM ROOF |
| | PANEL SYATEMS - IN ADDITION TO THE PROVISIONS IN |
| | SECTION D6.2.1, FOR LOAD COMBINATIONS THAT INCLUDE WIND |
| | UPLIFT, THE NOMINAL WIND LOAD SHALL BE PERMITTED TO BE |
| | MULTIPLIED BY 0.67 PROVIDED THE TESTED SYSTEM AND WIND |
| | LOAD EVALUATION SATIFIES THE FOLLOWING CONDITIONS: |
| | A. THE ROOF SYSTEM IS TESTED IN ACCORDANCE WITH AISI |
| | S906. |
| | B. THE WIND LOAD IS CALCULATED USING ASCE/SEI 7 FOR |
| | COMPONENTS AND CLADDING, METHOD 1 (SIMPLIFIED |
| | PROCEDURE) OR METHOD 2 (ANALYTICAL PROCEDURE). |
| | C. THE AREA OF THE ROOF BEING EVALUATED IS IN ZONE 2 |
| | (EDGE ZONE) OR ZONE 3 (CORNER ZONE). |
| | |
| | PLEASE INDICATE ON THE PLAN IF THIS OPTION WILL BE |
| | UTILIZED |
| | |
| | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT |
| | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY |
| | REVIEWED SHEETS DETACHED. |
| | |
| | |
| | |
| | |