| Plan Review Notes For Permit 18060100 |
| Permit Number |
18060100 |
|
| Review Stop |
B |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2018-08-22 13:08:48 | 1. OK. | | | | | | 2. OK. | | | | | | 3. [FBC ENERGY R401.2]PROVIDE ENERGY CALCULATIONS TO | | | MEET REQUIREMENTS IN R401.2 RESIDENTIAL ENERGY CODE. | | | UPDATE PLANS TO SHOW INSULATION VALUES FROM THE ENERGY | | | CALCULATIONS. | | | 3-2. NOT PROVIDED | | | | | | 4. [FBC ENERGY R401.3]PROVIDE ENERGY PERFORMANCE LEVEL | | | (ELP)DISPLAY CARD WITH THE ENEGRY CALCULATIONS TO SHOW | | | ESTIMATED ENERGY PERFORMANCE LEVEL. THIS CARD IS TO BE | | | SIGNED BY BUILDER AND AVAILABLE FOR INSPECTOR TO REVIEW | | | FOR BUILDING FINAL. | | | 4-2. NOT PROVIDED | | | | | | 5-17 OK. | | | | | | 18. [FBC 107.2.1]N.O.A. FOR WINDOW ONLY COVERS WINDOWS | | | UP TO 76" IN HEIGHT (TABLE 1&2). PLEASE PROVIDE N.O.A. | | | FOR WINDOWS OVER 76" TALL. | | | 18-2. NO NEW PRODUCT APPROVAL PROVIDED. | | | | | | NEW COMMENT: | | | 19. VERIFY THAT THE FOOTER FOR THE SITE WALL WILL NEED | | | TO BE WITHIN PROPERTY LINES. | | | IF THE WALL IS TO EXTEND TO THE PROPERTY LINE PROVIDE | | | DETAIL TO SHOW ECCENTRIC FOOTER TO KEEP THE FOOTER | | | WITHIN PROPERTY LINES, WHILE ALLOWING WALL TO EXTEND TO | | | PROPERTY LINE. | | | | | | 20. ROOFING WAS APPROVED, BUT A NEW PRODUCT APPROVAL | | | WAS SUBMITTED FOR SYSTEM OVER CONCRETE DECK. | | | PLEASE VERIFY THAT THIS DOESN'T APPLY TO THIS PROJECT. | | | I BELIEVE ALL ROOF DECK IS TO BE OVER PLYWOOD | | | SHEATHING. | | | | | | 18060108(DECK): | | | 1. OK. |
|