| 2018-08-09 15:17:35 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | FROM PREVIOUS LIST: | | | | | | 1. C5 WIND SPEED IS SHOWN AS 160 MPH (VULT), RISK | | | CATEGORY II. ADVISE HOW THIS WAS DETERMINED; IF RISK | | | CATEGORY II THIS SHOULD BE A MINIMUM OF 167, AND 179 | | | FOR RISK CATEGORY III-IV. FBC B 1609. | | | | | | 2ND REVIEW, NOT ADDRESSED. PLEASE REVISE TO A MINIMUM | | | OF 167MPH, EXPOSURE C. | | | | | | 2-3. OK | | | | | | NEW COMMENT: INFORMATIONAL ONLY - A CONTRACT WAS | | | PROVIDED. IT APPEARS THAT LANDSCAPING, FENCING WAS | | | INCLUDED IN THE VALUE OF THIS PERMIT. BOTH SHOULD BE A | | | SEPARATE PERMIT WITH SEPARATE FEES. VALUE HAS BEEN | | | ADJUSTED, RESULTING IN A CREDIT. | | | | | | PLEASE SUBMIT AN APPLICATION FOR EITHER LANDSCAPING OR | | | FENCING AT THIS TIME SO THE CREDIT CAN BE TRANSFERRED. | | | IF THE PERMIT DOCUMENTS FOR THESE ITEMS ARE NOT YET | | | AVAILABLE, A PERMIT APPLICATION NUMBER CAN STILL BE | | | GENERATED (WITH A PERMIT APPLICATION) AND WILL BE | | | RETAINED AT THE BUILDING DIVISION UNTIL THE TIME THAT | | | YOU ARE READY TO PROVIDE PERMIT DOCUMENTS. | | | | | | | | | | | | | | | |
|