| 2018-08-28 16:22:55 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, |
| | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: |
| | |
| | PLEASE CONSIDER THE FOLLOWING AS PROVISO: |
| | |
| | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED |
| | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE |
| | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE |
| | INSPECTION. |
| | |
| | |
| | 1) SHEET A 0.10 - THE LIFE SAFETY PLAN INDICATES REAR |
| | EXIT SIGNS LEADING THRU THE STORAGE AREA. |
| | |
| | PER NFPA 101, CHAPTER 7,MEANS OF EGRESS |
| | |
| | 7.5.1.6 EXIT ACCESS FROM ROOMS OR SPACES SHALL BE |
| | PERMITTED TO BE THROUGH ADJOINING OR INTERVENING ROOMS |
| | OR AREAS, PROVIDED THAT SUCH ROOMS OR AREAS ARE |
| | ACCESSORY TO THE AREA SERVED. FOYERS, LOBBIES, AND |
| | RECEPTION ROOMS CONSTRUCTED AS REQUIRED FOR CORRIDORS |
| | SHALL NOT BE CONSTRUED AS INTERVENING ROOMS. EXIT |
| | ACCESS SHALL BE ARRANGED SO THAT IT IS NOT NECESSARY TO |
| | PASS THROUGH ANY AREA IDENTIFIED UNDER PROTECTION FROM |
| | HAZARDS IN CHAPTERS 11 THROUGH 43. |
| | |
| | A STORAGE ROOM IS IDENTIFIED AS ONE OF THESE AREAS. |
| | |
| | HOWEVER, ONLY ONE EXIT IS REQUIRED FROM THE MAIN |
| | MERCANTILE AREA AND ONE FROM THE STORAGE ROOM. |
| | |
| | 36.2.4 NUMBER OF MEANS OF EGRESS. |
| | 36.2.4.1 MEANS OF EGRESS SHALL COMPLY WITH ALL OF THE |
| | FOLLOWING, |
| | EXCEPT AS OTHERWISE PERMITTED BY 36.2.4.2 THROUGH |
| | 36.2.4.5: |
| | (1) THE NUMBER OF MEANS OF EGRESS SHALL BE IN |
| | ACCORDANCE WITH |
| | SECTION 7.4. |
| | (2) NOT LESS THAN TWO SEPARATE EXITS SHALL BE PROVIDED |
| | ON EVERY |
| | STORY. |
| | (3) NOT LESS THAN TWO SEPARATE EXITS SHALL BE |
| | ACCESSIBLE FROM |
| | EVERY PART OF EVERY STORY. |
| | |
| | 36.2.4.3 A SINGLE MEANS OF EGRESS SHALL BE PERMITTED IN |
| | A CLASS C |
| | MERCANTILE OCCUPANCY, PROVIDED THAT THE TRAVEL DISTANCE |
| | TO THE EXIT |
| | OR TO A MALL PEDESTRIAN WAY (SEE 36.4.4.2) DOES NOT |
| | EXCEED 75 FT |
| | (23 M). |
| | |
| | MOVE ONE EXIT SIGN IN THE HALL LEADING TO THE FRONT |
| | EXIT AND REMOVE THE ONE OVER THE STORAGE ROOM DOOR. |
| | |
| | |
| | 2) ANY WORK OF THE FIRE SPRINKLER AND/OR FIRE ALARM |
| | SHALL BE DONE UNDER SEPARATE SHOP DRAWINGS. |
| | |
| | |
| | PETER LEDUC |
| | FIRE MARSHAL |
| | 561-804-4709 |
| | [email protected] |
| | |